2011
DOI: 10.1016/j.talanta.2010.08.017
|View full text |Cite
|
Sign up to set email alerts
|

Anionic forensic signatures for sample matching of potassium cyanide using high performance ion chromatography and chemometrics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 15 publications
(14 citation statements)
references
References 7 publications
0
14
0
Order By: Relevance
“…Figure shows resolution of NaCN and KCN based on four anions (unk5, SO 4 , OX, and PO 4 ) into three main clusters (GE/BE, CZ, US/UK/ES), consistent with three factories (GE, CZ, and US) and inclusive of both KCN and NaCN samples. The four anions responsible for the observed clustering were previously selected using F-ratio analysis of the 11 original anions and resulted in tighter clusters based on country of origin as opposed to using 11 anions . Given that the combined HPIC data in this paper had potentially new and significant sources of data variance (e.g., from different operators, different HPIC systems, and new stocks), HCA and PCA was performed on the combined HPIC data starting with all 11 anions (unk1, unk2, Cl, unk3, NO 2 , unk4, CO 3 , unk5, SO 4 , OX, and PO 4 ) in order to detect any obvious outliers in regards to sample clustering according to source.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Figure shows resolution of NaCN and KCN based on four anions (unk5, SO 4 , OX, and PO 4 ) into three main clusters (GE/BE, CZ, US/UK/ES), consistent with three factories (GE, CZ, and US) and inclusive of both KCN and NaCN samples. The four anions responsible for the observed clustering were previously selected using F-ratio analysis of the 11 original anions and resulted in tighter clusters based on country of origin as opposed to using 11 anions . Given that the combined HPIC data in this paper had potentially new and significant sources of data variance (e.g., from different operators, different HPIC systems, and new stocks), HCA and PCA was performed on the combined HPIC data starting with all 11 anions (unk1, unk2, Cl, unk3, NO 2 , unk4, CO 3 , unk5, SO 4 , OX, and PO 4 ) in order to detect any obvious outliers in regards to sample clustering according to source.…”
Section: Resultsmentioning
confidence: 99%
“…Variable selection was performed using the F-ratio method, iPLS, and GAPLS. The performance of four anion variables (unk5, SO 4 , OX, and PO 4 ) selected in reference was also evaluated for comparison. The number of latent variables (LVs) required for PLS calibrations used in the models (PLSDA, iPLS, and GAPLS) were computed by the software using cross-validation.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The impurity profiling work described here has precedence in previous forensic research on other chemical-threat agents and precursors [16][17][18]. In those studies, the feasibility of obtaining forensic information from impurity profiling for sample matching and possible route and source determination were demonstrated.…”
Section: Introductionmentioning
confidence: 92%