Abstract:

Approaches to control the microstructure of hydrogels enable the control of cell–material interactions and the design of stimuli-responsive materials.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
14
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(15 citation statements)
references
References 58 publications
1
14
0
Order By: Relevance
“…Samples were immersed in PBS buffer at 37°C for 24 h to swell fully and then lyophilized overnight; after that, the cross-sections of dried hydrogels were prepared using a blade and coated with a thin layer of sputtered gold for 120 s. The cross-sectional morphology of the hydrogel samples was determined using a scanning electron microscope (JSM-5900, JEOL, Japan). ImageJ software (Nation Institutes of Health, Bethesda, MD, USA) was used to analyze the pore size and distribution through SEM images. , …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Samples were immersed in PBS buffer at 37°C for 24 h to swell fully and then lyophilized overnight; after that, the cross-sections of dried hydrogels were prepared using a blade and coated with a thin layer of sputtered gold for 120 s. The cross-sectional morphology of the hydrogel samples was determined using a scanning electron microscope (JSM-5900, JEOL, Japan). ImageJ software (Nation Institutes of Health, Bethesda, MD, USA) was used to analyze the pore size and distribution through SEM images. , …”
Section: Methodsmentioning
confidence: 99%
“…ImageJ software (Nation Institutes of Health, Bethesda, MD, USA) was used to analyze the pore size and distribution through SEM images. 37,38 2.4. Compressive Modulus Test.…”
Section: Cross-sectional Morphologymentioning
confidence: 99%
“…Nuclear alignment on different micropatterns of aligned collagen fibrils and control was computed using "Fit Ellipse" in ImageJ software as outlined previously. 28 The angle between the major axis of the nuclei that fitted into an ellipse and the horizontal axis of the image was measured. These angles were used to measure the orientation index (OI) as an indicator of the overall cell alignment with 100% OI indicating alignment of the nucleus with the underlying fibrils (i.e., along the horizontal).…”
Section: Coating Of Pdms-coated Glass Coverslips With Monomericmentioning
confidence: 99%
“…Various hydrogel structures are obtained by harnessing LCLC phases, obtained by just varying polymerization temperatures. 34…”
Section: Molecular Design Of Lyotropic Chromonic Liquid Crystalline Materialsmentioning
confidence: 99%