2001
DOI: 10.1016/s0149-1970(00)00119-0
|View full text |Cite
|
Sign up to set email alerts
|

Annealing effects of helium implanted single crystals and polycrystalline magnesium aluminate spinel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2002
2002
2006
2006

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 6 publications
0
9
0
Order By: Relevance
“…The He shift towards the surface suggests that He atoms are mobile at temperatures as low as 600°C and are trapped at implantation induced defects as has already been observed in crystalline Si [10] and also in polycrystalline MgAl 2 O 4 [11]. Corni et al [10] observed a forward He profile shift of 45 nm in 20 keV heliumimplanted silicon (R p ¼ 215 nm) after annealing.…”
Section: Discussion Of Experimental Resultsmentioning
confidence: 77%
See 1 more Smart Citation
“…The He shift towards the surface suggests that He atoms are mobile at temperatures as low as 600°C and are trapped at implantation induced defects as has already been observed in crystalline Si [10] and also in polycrystalline MgAl 2 O 4 [11]. Corni et al [10] observed a forward He profile shift of 45 nm in 20 keV heliumimplanted silicon (R p ¼ 215 nm) after annealing.…”
Section: Discussion Of Experimental Resultsmentioning
confidence: 77%
“…By correlating ERD, PAS and DC-XRD measurements, the authors ascribed this 14% shift to the interstitial helium movement and trapping in the vacancy-like defects produced by the implantation. A forward shift of the maximum helium concentration was also observed in polycrystalline MgAl 2 O 4 implanted with 900 keV 3 He þ ions [11]. The authors ascribed this shift to helium trapping in pores.…”
Section: Discussion Of Experimental Resultsmentioning
confidence: 85%
“…The use of the implantation technique to obtain the 3 He standard needs to correct the incident deuteron energy value. At the depth of 130 nm, the 322-1000 keV range corresponds to an energy range between 307 and 992 keV for which the 3 He(d, p) 4 He differential cross-section is measured (Fig. 1).…”
Section: Cross-section Measurementsmentioning
confidence: 99%
“…Recently, some studies have been devoted to the helium behavior in nuclear materials. Indeed, the principal source of radiation during long term storage of nuclear wastes (glasses or spent fuels) and in matrices for transmutation is a decay of actinides [1][2][3][4][5][6][7]. Amounts of helium could be large, and depending on temperature, this can change the chemical and mechanical stability of the materials.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation