Order By: Relevance
“…In total, 1213 and 2316 peak pairs or metabolites could be detected in CSF and serum, respectively, and 102 CSF and 108 serum metabolites could be positively identified. Compared to previous work on metabolome profiling that typically reports less than 100 amine- and phenol-containing metabolites1720, dansylation labeling LC-MS achieved a much higher coverage for this targeted sub-metabolome.…”
Section: Discussionmentioning
confidence: 81%
“…In total, 1213 and 2316 peak pairs or metabolites could be detected in CSF and serum, respectively, and 102 CSF and 108 serum metabolites could be positively identified. Compared to previous work on metabolome profiling that typically reports less than 100 amine- and phenol-containing metabolites1720, dansylation labeling LC-MS achieved a much higher coverage for this targeted sub-metabolome.…”
Section: Discussionmentioning
confidence: 81%
“…Chromatographic conditions were adapted to screen microbiota-derived metabolites as described 22. Data were curated, normalised and annotated, yielding 242 different metabolites.…”
Section: Methodsmentioning
confidence: 99%
“…A (2015), http://dx.doi.org/10.1016/j.chroma.2015.08.059 only ionize in positive or negative mode. This is illustrated by the data shown collected by Boudah et al in Table 1 [43]. For example, 130 metabolites were detected using negative mode with a HILIC (hydrophilic interaction chromatography) column, where 103 compounds can be identified without the need of another chromatographic method.…”
Section: Mass Spectramentioning
confidence: 94%
“…Separation strategies for untargeted metabolomics were reviewed previously, and include suggestions for potential column chemistries and ion pairing agents that can be implemented [42]. By using three different column chemistries (reverse phase, HILIC, and PFPP), Boudah et al determined that less than 12% of the detected entities were detected in all three separations [43], which emphasizes the advantage of analyzing samples under different conditions. This is also illustrated by the data shown in Table 1.…”
Section: Chromatographymentioning
confidence: 99%
See 1 more Smart Citation