Anode current saturation of ALD-coated Planacon® MCP-PMTs

Abstract: We have measured and compared the characteristics of ALD-coated Planacon ® MCP-PMTs (XP85112/A1-Q-L) with their non-ALD counterparts (XP85012/A1-Q). While the later show excellent performance, the ALD-coated sensors have surprisingly low current saturation levels (~two orders of magnitude lower than expected) and extremely high gain recovery time (more than 7 orders of magnitude higher than expected). We suspect that these problems might be caused by the unexpected side-effects of the ALD process. To make a de… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
5
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 14 publications
2
5
0
Order By: Relevance
“…A new, surprising, effect was observed: all tested tubes lost their gain for quite a long time after being exposed to the high signal rates. This observation was made also by ALICE group [10] and the effect was confirmed also for an ALD coated tube produced by Photek Ltd. A small study Relative signal value of the tested MCP-PMTs normalized to that of the reference PMT versus integrated number of counts (digitized pulse waveforms) [11]. [11] comparing tubes, with properties summarized in Figure 14, was made.…”
Section: Mcp-pmt and High Signal Ratessupporting
confidence: 53%
See 1 more Smart Citation
“…A new, surprising, effect was observed: all tested tubes lost their gain for quite a long time after being exposed to the high signal rates. This observation was made also by ALICE group [10] and the effect was confirmed also for an ALD coated tube produced by Photek Ltd. A small study Relative signal value of the tested MCP-PMTs normalized to that of the reference PMT versus integrated number of counts (digitized pulse waveforms) [11]. [11] comparing tubes, with properties summarized in Figure 14, was made.…”
Section: Mcp-pmt and High Signal Ratessupporting
confidence: 53%
“…A new, surprising, effect was observed: all tested tubes lost their gain for quite a long time after being exposed to the high signal rates. This observation was made also by ALICE group [10] and the effect was confirmed also for an ALD coated tube produced by Photek Ltd. A small study comparing tubes, with properties summarized in table 2, was made [11]. The measurements of the recoverability time for each MCP-PMT is shown in figure 14.…”
Section: Mcp-pmt and High Signal Ratessupporting
confidence: 52%
“…The design details and results of tests of several FIT detector prototypes have already been published before (see [2][3][4][5][6]), as well as the simulated detector performance (see [7,8]). The focus of this paper is on the final FEE and its response to signals from real detectors.…”
Section: Test Resultsmentioning
confidence: 99%
“…Laser light intensity was set constant throughout the measurement for each set of MCP-PMTs and monitored independently by the reference PMT, which was biased to a fixed voltage. The repetition rate was set to 1 kHz to mitigate the influence of the average anode current saturation [17,18]. The gain scan was performed by increasing the bias voltage in 25 or 50 V steps.…”
Section: Absolute Gain Calibrationmentioning
confidence: 99%