Anterior atlanto-occipital transarticular screw fixation: a biomechanical comparison with posterior fixation techniques

Abstract: OBJECTIVE Atlanto-occipital instability is commonly treated with posterior fixation. However, in patients with congenital or acquired factors, posterior fixation may not be possible. For these situations, a novel anterior atlanto-occipital transarticular screw (AATS) fixation technique has been introduced recently. However, biomechanical study of this technique is lacking. This study was designed to evaluate the biomechanical stability of AATS fixation for the atlanto-occipital joint and compare it with conven… Show more