2021
DOI: 10.1002/admi.202001812
|View full text |Cite
|
Sign up to set email alerts
|

Antisolvent‐Induced Fastly Grown All‐Inorganic Perovskite CsPbCl3 Microcrystal Films for High‐Sensitive UV Photodetectors

Abstract: Figure 4. Characterization of the stability of the CsPbCl 3 MCFs and CsPbCl 3 MCFs-based UV-PDs. a) Comparison of the powder XRD patterns of the CsPbCl 3 MCFs freshly prepared and after storage in air environment for 5 months. b) Normalized IT curve of the CsPbCl 3 MCF UV-PDs under continuous and periodic (inset) 365 nm light illumination.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
32
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(35 citation statements)
references
References 49 publications
3
32
0
Order By: Relevance
“…Under 365 nm illumination, the device achieved responsivity of 2.11 A W À1 and rise/decay time of 77 ms/63 ms (Figure 9e,f ). [69] The difference between the results of the two studies may be mainly due to the different grain size of CsPbCl 3 films, which could affect the transport of carriers. Under 365 nm light irradiation and 15 V bias, the photodetector was reported to achieve a responsivity of 2.27 A W À1 , an external quantum efficiency of 772%, and detectivity of 6.07 Â 10 11 Jones (Figure 10b-d).…”
Section: Cspbx 3 (X ¼ Br Cl)mentioning
confidence: 96%
See 2 more Smart Citations
“…Under 365 nm illumination, the device achieved responsivity of 2.11 A W À1 and rise/decay time of 77 ms/63 ms (Figure 9e,f ). [69] The difference between the results of the two studies may be mainly due to the different grain size of CsPbCl 3 films, which could affect the transport of carriers. Under 365 nm light irradiation and 15 V bias, the photodetector was reported to achieve a responsivity of 2.27 A W À1 , an external quantum efficiency of 772%, and detectivity of 6.07 Â 10 11 Jones (Figure 10b-d).…”
Section: Cspbx 3 (X ¼ Br Cl)mentioning
confidence: 96%
“…Under 365 nm illumination, the device achieved responsivity of 2.11 A W −1 and rise/decay time of 77 ms/63 ms (Figure 9e,f). [ 69 ] The difference between the results of the two studies may be mainly due to the different grain size of CsPbCl 3 films, which could affect the transport of carriers.…”
Section: Ultraviolet Light Photodetectorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Due to the extremely low solubility of the CsCl precursor in existing solvents, almost all of the CsPbCl 3 photodetectors previously reported are composed of CsPbCl 3 micro- or nanostructures, whereas the preparation of a high-quality CsPbCl 3 polycrystalline film still remains a big challenge. The research studies on CsPbCl 3 photodetector started late compared to other types of perovskite photodetectors.…”
Section: Introductionmentioning
confidence: 99%
“…Very recently, Yang’s group put forward an antisolvent-assisted crystallization recipe to prepare continuous CsPbCl 3 microcrystal films. The best-performing photodetector based on the film delivered a high D * of 5.6 × 10 12 Jones and an R of 2.11 A/W at a 4 V bias . Single crystals of CsPbCl 3 were also employed to detect UV signals but the D * was considerably low (1.588 × 10 10 Jones) .…”
Section: Introductionmentioning
confidence: 99%