2016 IEEE International Conference on Dielectrics (ICD) 2016
DOI: 10.1109/icd.2016.7547648
|View full text |Cite
|
Sign up to set email alerts
|

“Apparent” and true charges of partial discharges

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2017
2017
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 4 publications
0
2
0
1
Order By: Relevance
“…Form and size of electrode system including needle was introduced into simulation, point by point by using of electrode system photo image. [35,36] The electrode system capacitance and electric field with bubbles and no bubbles within the dielectrics is determined by calculating the distribution of potential E=-grad u. In simple case when bubble axis coincides with the axis of the electrode system, the potential distribution u can be obtained by solving a two-dimensional problem in a cylindrical coordinate system, > @`0 3with boundary conditions (4) was performed using the subsystem of the own TELMA software package [36].…”
Section: Pd In Case Of Point-plane Electrode Systemmentioning
confidence: 99%
“…Form and size of electrode system including needle was introduced into simulation, point by point by using of electrode system photo image. [35,36] The electrode system capacitance and electric field with bubbles and no bubbles within the dielectrics is determined by calculating the distribution of potential E=-grad u. In simple case when bubble axis coincides with the axis of the electrode system, the potential distribution u can be obtained by solving a two-dimensional problem in a cylindrical coordinate system, > @`0 3with boundary conditions (4) was performed using the subsystem of the own TELMA software package [36].…”
Section: Pd In Case Of Point-plane Electrode Systemmentioning
confidence: 99%
“…В настоящее время в условиях эксплуатации широко применяется диагностика состояния изоляции по параметрам частичных разрядов (ЧР). Однако теория, описывающая влияние различных режимных параметров, климатических факторов, факторов, определяющих старение изоляции на изменение параметров частичных разрядов, в полном объеме не разработана [1][2][3][4][5][6].…”
Section: Introductionunclassified
“…The PD pulses have been reported to have a rise time of fewer than 2 ns and the frequency contents to be in the range of hundreds of megahertz to a few gigahertz [10]. The PD signal measured at the transformer terminals is only indicative of the discharge [11] and the nature of propagation of the impinging fields through the windings is not known quantitatively. To tackle these issues and to get a better resolution and accuracy in the required frequency range, multi‐conductor transmission‐line (MTL) model has been used [4, 1215].…”
Section: Introductionmentioning
confidence: 99%