2016
DOI: 10.1002/rcm.7505
|View full text |Cite
|
Sign up to set email alerts
|

Applicability of gas chromatography/quadrupole‐Orbitrap mass spectrometry in support of pharmaceutical research and development

Abstract: GC/Orbitrap MS has been evaluated for both qualitative and quantitative analysis of typical pharmaceutical precursors and impurities. Accurate mass measurement across a wide dynamic range, linearity and the ability to identify impurities in EI and CI illustrate that this instrument is a powerful tool of great benefit to pharmaceutical analysis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 17 publications
(13 citation statements)
references
References 17 publications
(20 reference statements)
0
13
0
Order By: Relevance
“…It allows the analytes to condense into a tight band on the head of the column. The split valve will be opened after the split time to flush the injection of any residual specimen [39]. Another injection method that is beneficial to eliminate injector or column contamination is used this is called headspace injection.…”
Section: Gc-msmentioning
confidence: 99%
“…It allows the analytes to condense into a tight band on the head of the column. The split valve will be opened after the split time to flush the injection of any residual specimen [39]. Another injection method that is beneficial to eliminate injector or column contamination is used this is called headspace injection.…”
Section: Gc-msmentioning
confidence: 99%
“…On the other hand, the developments in Atmospheric Pressure Gas Chromatography (APGC) [59] and the recent introduction of an GCcompatible orbitrap mass analyzer seem to turn this trend. The second was already applied in a pharmaceutical setting beyond determination of residual solvents [60]. The combination of these new instruments with the advantage of electron ionization (EI) and concurrent spectral library searching has the potential to introduce a paradigm shift in the choice of MS inlet system (LC versus GC).…”
Section: Technological Advancements Facilitating Data Acquisitionmentioning
confidence: 99%
“…Hence, the use of GC-MS for targeted and non-targeted metabolic studies, especially for breathomics, is highly suitable and powerful [ 15 ]. In recent years, GC-HRMS has gained popularity [ 16 ]. GC-Orbitrap provides a high mass resolving power (120,000 full width at half maximum (FWHM) at ( m / z 200)) combined with a high mass accuracy (<5 ppm), which is needed to avoid isobaric interference [ 17 ].…”
Section: Introductionmentioning