Application of a fast electrical pulse in gated multichannel plate camera

Abstract: An eight-frame gated microchannel plate (MCP) camera and a gating electrical pulse are described in this article. The gating electrical pulse is obtained by first generating a high voltage fast step pulse using avalanche transistors in Marx bank configuration, and then shaping it using avalanche diodes. The high voltage fast step pulse is about 200 ps in fall time and 4 kV in amplitude. The gating pulse wave form with width of 160 ps and amplitude of 2.5 kV is achieved. Each frame photocathode coated with gold… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(10 citation statements)
references
References 12 publications
0
10
0
Order By: Relevance
“…Owing to the wide width (20 mm) of the strip line, four gating electrical pulses were employed to drive the whole strip line simultaneously to obtain a uniform gain. A high voltage ramp pulse generated by avalanche transistor circuit was used to drive two sharpening avalanche diode circuits [35]. Each of the sharpening avalanche diode circuits can produce two picosecond gating pulses.…”
Section: Research Articlementioning
confidence: 99%
See 1 more Smart Citation
“…Owing to the wide width (20 mm) of the strip line, four gating electrical pulses were employed to drive the whole strip line simultaneously to obtain a uniform gain. A high voltage ramp pulse generated by avalanche transistor circuit was used to drive two sharpening avalanche diode circuits [35]. Each of the sharpening avalanche diode circuits can produce two picosecond gating pulses.…”
Section: Research Articlementioning
confidence: 99%
“…The exposure time measurement was similar to [35]. An ultraviolet laser (266 nm) with 30 ps duration was used as the calibration light source.…”
Section: Research Articlementioning
confidence: 99%
“…The pulses are obtained by first generating a high voltage fast step pulse using avalanche transistors in a Marx bank configuration and then shaping it using avalanche diodes. 14 This creates short pulses with a width of 220 ps and an amplitude of −1.9 kV (Fig. 2(b)).…”
Section: -mentioning
confidence: 99%
“…The structure of the nongain MCP framing camera is the same as the previous MCP gated framing camera. 1 The simulations of the nongain MCP are started by assuming some number of initial photoelectrons near the input end of the MCP. The photoelectron energy is sampled randomly from a Maxwell probability distribution, and the emission angle of each photoelectron is assigned by sampling from a cosine distribution.…”
Section: ͑6͒mentioning
confidence: 99%
“…1 Typically, exposure time of a framing camera gated by a MCP 0.5 mm thick is about 100 ps. The shortest exposure time of 35 ps was achieved by using a gated MCP 0.2 mm thick.…”
Section: Introductionmentioning
confidence: 99%