2003
DOI: 10.1556/jpc.16.2003.3.1
|View full text |Cite
|
Sign up to set email alerts
|

Application of a horizontal DS chamber to planar electrochromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
0

Year Published

2004
2004
2015
2015

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 31 publications
(11 citation statements)
references
References 8 publications
0
11
0
Order By: Relevance
“…This effect was reduced to some extent by application of an appropriate buffer concentration in the mobile phase, [11] or a special strip of counter plate fixed to the adsorbent layer between solvent entry position and start line of the sample. [13] However, these attempts were not satisfactory and reproducibility of retention was still worse than in a TLC mode.…”
Section: Introductionmentioning
confidence: 99%
“…This effect was reduced to some extent by application of an appropriate buffer concentration in the mobile phase, [11] or a special strip of counter plate fixed to the adsorbent layer between solvent entry position and start line of the sample. [13] However, these attempts were not satisfactory and reproducibility of retention was still worse than in a TLC mode.…”
Section: Introductionmentioning
confidence: 99%
“…Another solution was presented in a paper by our group. We have proposed restricted feeding of the chromatographic plate with the mobile phase solution from the reservoir . The plate number obtained in these systems was several times larger than that in conventional TLC.…”
mentioning
confidence: 99%
“…Apparatus for ion-exchange planar electrochromatography. (1, 2) platform, (3) eluent dish, (4) ion-exchange plate chamber, (5, 6) electrode, (7) collecting tube, (8) T-tube, (9) power supply, (10) peristaltic pump, (11) UV detector, (12) fraction collector, (13) computer, (14) printer.…”
Section: Reagents and Apparatusmentioning
confidence: 99%
“…[10][11][12][13] Dzido et al applied a commercially available horizontal chamber to the planar electrochromatographic separation of a dye mixture on non-polar stationary phases. [14,15] Polak et al used pressurized planar electrochromatography with chiral plates to separate the enantiomers of tryptophan and valine. [16] Tate and Dorsey built an instrument composed of three sections: PEC base, cover grid, and voltage divider box.…”
Section: Introductionmentioning
confidence: 99%