2017
DOI: 10.1016/j.snb.2017.03.156
|View full text |Cite
|
Sign up to set email alerts
|

Application of a tyrosinase microreactor – detector in a flow injection configuration for the determination of affinity and dynamics of inhibitor binding

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
2
0
8

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 61 publications
1
2
0
8
Order By: Relevance
“…As expected from these observations, the results of the paired t-test (p < 0.01) revealed that the immobilized tyrosinase was more stable during storage than the free tyrosinase solution. In addition, when compared to the stability results of tyrosinase immobilized using a range of methods (see Table 2), these data confirm that the immobilization method used herein is superior to previously reported methods (16)(17)(18)(19)). Regression-plot repeatability was determined using TYR-MNPs from batch 1, the results of which are listed in Table 3.…”
Section: Tyr-mnp Reusability and Stabilitysupporting
confidence: 84%
“…As expected from these observations, the results of the paired t-test (p < 0.01) revealed that the immobilized tyrosinase was more stable during storage than the free tyrosinase solution. In addition, when compared to the stability results of tyrosinase immobilized using a range of methods (see Table 2), these data confirm that the immobilization method used herein is superior to previously reported methods (16)(17)(18)(19)). Regression-plot repeatability was determined using TYR-MNPs from batch 1, the results of which are listed in Table 3.…”
Section: Tyr-mnp Reusability and Stabilitysupporting
confidence: 84%
“…As an example, a colorimetric assay based on a combination of chitosan-stabilized platinum nanoparticels, catechol, tyrosinase, and 3,3',5,5'-tetramethylbenzidine as the probe being oxidized to a yellow diamine has been proposed [221]. A microreactor-detector based on the use of a gold disk for tyrosinase immobilization and a carbon disk as a working electrode able to amperometrically detect dopaquinone formation starting from l-tyrosine has also been described [222]. Immobilized tyrosinase has been used also coupled to capillary electrophoresis [223,224].…”
Section: New Trends In the Search For Tyrosinase Inhibitorsmentioning
confidence: 99%
“…In other words, sensitive and correct assay methods for screening and development of effective tyrosinase inhibitors are of great importance. For this purpose, several spectrophotometric 6–10 , chromatographic 11–17 , electrophoretic 18–22 , radiometric 23 , 24 and electrochemical 25–27 assays have been applied and developed by researchers so far. Recently, a novel fluorescent biosensor 28 and tyrosinase-based thin-layer chromatography-autography have been suggested for tyrosinase inhibitor screening 29 .…”
Section: Introductionmentioning
confidence: 99%