2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230)
DOI: 10.1109/pesc.2001.954161
|View full text |Cite
|
Sign up to set email alerts
|

Application of averaged models to real-time monitoring of power converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…[12], uses an approximated expression of power loss in each phase of the converter to define the number of working phases, but this method is not really accurate. [7] and [13] propose to store the number of working phases for different operating points (output current, input voltage and duty cycle) of the converter in a look-up table. This approach is quite tedious as experimental tests are required for many operating points for each configuration (1, 2 or 3 phases) of the converter to establish this table.…”
Section: Multiphase Converters To Increase Power Range At High Efficimentioning
confidence: 99%
See 1 more Smart Citation
“…[12], uses an approximated expression of power loss in each phase of the converter to define the number of working phases, but this method is not really accurate. [7] and [13] propose to store the number of working phases for different operating points (output current, input voltage and duty cycle) of the converter in a look-up table. This approach is quite tedious as experimental tests are required for many operating points for each configuration (1, 2 or 3 phases) of the converter to establish this table.…”
Section: Multiphase Converters To Increase Power Range At High Efficimentioning
confidence: 99%
“…The approaches proposed by [13] and [15] are based on a precise analysis of the switching process. As these approaches are difficult to implement (typically measurements for different operating conditions of the converter cannot be automated), we propose to directly identify the total losses in one elementary converter without any distinction of switching, conduction and copper losses.…”
Section: Losses Modelingmentioning
confidence: 99%
“…As noted in [6], the power loss determinations during switching conditions and the parameters of the switching devices according to the datasheets [7] shows that the performance of switching components is not sufficiently accurate for such an application. The methods proposed by [8] and [9] are based on a precise analysis of the switching conditions. Because these methods are difficult to using and usually measurements cannot be obtained for the different operating conditions of the converter circuit, thus it is recommended to directly identify the total losses without any switching and conduction losses.…”
Section: Introductionmentioning
confidence: 99%
“…The monitoring of their values is at a premium to ensure reliable operation. Extensive work and literature relate techniques based upon an estimator to avoid the cost and pitfalls of dedicated sensors [1][2][3]. The method proposed in this paper is based on the measurement of the drain source voltage at the terminals of one MOSFET in an inverter.…”
Section: Introductionmentioning
confidence: 99%