2021
DOI: 10.1016/j.cej.2021.131268
|View full text |Cite
|
Sign up to set email alerts
|

Application of cerium and lanthanum coagulants in wastewater treatment—A comparative assessment to magnesium, aluminum, and iron coagulants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 35 publications
0
12
0
Order By: Relevance
“…Many absorption peaks existed at 950–1300 cm –1 , which should be the absorption peak of SO 4 2– . , There were two strong absorption peaks with the peak of Fe–OH–Fe at 1100 cm –1 and the peak of Al–OH–Al at 1150 cm –1 , respectively . The positions of the two peaks were similar and belonged to the bending vibration of Me–OH on the molecular surface . It shows that both hydroxyl-linked polymeric iron and hydroxyl-bridged polymeric aluminum existed in PAFS.…”
Section: Resultsmentioning
confidence: 85%
See 1 more Smart Citation
“…Many absorption peaks existed at 950–1300 cm –1 , which should be the absorption peak of SO 4 2– . , There were two strong absorption peaks with the peak of Fe–OH–Fe at 1100 cm –1 and the peak of Al–OH–Al at 1150 cm –1 , respectively . The positions of the two peaks were similar and belonged to the bending vibration of Me–OH on the molecular surface . It shows that both hydroxyl-linked polymeric iron and hydroxyl-bridged polymeric aluminum existed in PAFS.…”
Section: Resultsmentioning
confidence: 85%
“…42 The positions of the two peaks were similar and belonged to the bending vibration of Me− OH on the molecular surface. 43 It indicates that the hydrolysis of Fe 3+ was carried out at a low basicity, while the hydrolysis degree of Al 3+ was low at the same condition. 44 The result of SEM shows that the samples of PAFS generally existed as a formless material.…”
Section: Structure and Characterization Of Polymersmentioning
confidence: 93%
“…It is also important to consider the impact of different types of coagulants on overall operating costs, including pipeline maintenance and downstream water treatment. Kajjumba et al (2021) found that Mg (OH) 2 was the cheapest coagulant, but struvite formed in pipes increased the overall operating costs; FeCl 3 , alum and Na 2 Al 2 O 4 were slightly more expensive than Mg (OH) 2 , but higher sludge yields roughly doubled the total cost; lanthanides, although high in unit price, had low sludge yields. Therefore, the use of coagulants depends firstly on their effectiveness and secondly on their operating costs relative to alternative compounds.…”
Section: Practical Application Of Coagulation For Cyanobacteria Controlmentioning
confidence: 99%
“…Zhou et al employed polyaluminum chloride (PAC) and ferric chloride (FeCl 3 ) as coagulants and successfully achieved effective degradation of polystyrene (PS) and polyethylene (PE) . Nevertheless, the utilization of coagulants is expensive, and eliminating relatively large MPs is challenging . Electrocoagulation is an innovative method for MPs degradation based on electrochemical technology, which does not require chemicals from chemical coagulation reactions or microorganisms from activated sludge processes .…”
Section: Current Technologies For Mps Conversionmentioning
confidence: 99%