Application of chelating ion exchange resins for trace element analysis of geological samples using x-ray fluorescence

Abstract: abundance for any one permutation formula is larger than that for the original formula, the mass of the permutation formula is computed, and a check is made to determine the existence of an ion corresponding to that mass in the spectrum. If the ion corresponding to the more abundant permutation formula is not found, the less abundant original formula is rejected. In other words, if any one of the permutations which are more abundant is not found, the formula is unsatisfactory.The final printed output is shown … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
36
1

Year Published

1974
1974
2013
2013

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 77 publications
(38 citation statements)
references
References 16 publications
1
36
1
Order By: Relevance
“…They have been reported for their extensive use in separation and concentration of metal ions [8][9][10][11][12] .They are useful in mineral processing industries as float aids, depressants, flocculants and collectors. Chelax 100 has been reported to be extensively used .Chelax 100 resin (styrene divinylbenzenecopolymer containing iminodiacetic acid) is used for preconcentration and separation of rare earth and heavy metals in pH range of 6-8 but they exhibit the disadvantage that the affinity of resins for alkaline earth metal is similar to that of transition ions.…”
Section: Imentioning
confidence: 99%
“…They have been reported for their extensive use in separation and concentration of metal ions [8][9][10][11][12] .They are useful in mineral processing industries as float aids, depressants, flocculants and collectors. Chelax 100 has been reported to be extensively used .Chelax 100 resin (styrene divinylbenzenecopolymer containing iminodiacetic acid) is used for preconcentration and separation of rare earth and heavy metals in pH range of 6-8 but they exhibit the disadvantage that the affinity of resins for alkaline earth metal is similar to that of transition ions.…”
Section: Imentioning
confidence: 99%
“…And, it has a relatively high affinity for calcium (II) and magnesium (II), that of calcium (II) being equal to that of zinc (II) (20,26,32,92).…”
Section: Concentration Of Trace Metalsmentioning
confidence: 99%
“…It has been usea in studies of food extracts (21), brines (22,23), Industrial waste water (l8, 24), sea water (25)(26)(27)(28)(29) and others (30)(31)(32). However, this is a gel-type resin which undergoes pronounced shrinking and swelling and has rather slow kinetics.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…and for the determination of low levels of cadmium in foods (86). Chelex 100 has been used as a medium for concentrating traces of some elements and, subsequently, as a sample matrix for the determination of those elements by X-ray fluorescence (87,88).…”
mentioning
confidence: 99%