2019
DOI: 10.1016/j.forsciint.2018.12.022
|View full text |Cite
|
Sign up to set email alerts
|

Application of differential scanning calorimetry in the analysis of apprehended formulations of anabolic androgenic steroids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 11 publications
(18 citation statements)
references
References 19 publications
0
18
0
Order By: Relevance
“…The evaluation of extraction methods is recurrent in the literature for several classes of substances. Nonetheless, few works compare the analytical procedures developed in the literature for the analysis of formulation of AASs, which is important in forensic science, given that the results are used as criminal evidence 10 . Among research studies, da Justa Neves and Caldas reported that there was a 5% increase in the recovery of testosterone, nandrolone, or trenbolone esters from oily formulations using ultrasonic bath compared with liquid–liquid or solid–liquid extraction.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…The evaluation of extraction methods is recurrent in the literature for several classes of substances. Nonetheless, few works compare the analytical procedures developed in the literature for the analysis of formulation of AASs, which is important in forensic science, given that the results are used as criminal evidence 10 . Among research studies, da Justa Neves and Caldas reported that there was a 5% increase in the recovery of testosterone, nandrolone, or trenbolone esters from oily formulations using ultrasonic bath compared with liquid–liquid or solid–liquid extraction.…”
Section: Discussionmentioning
confidence: 99%
“…According to the World Health Organization, falsified pharmaceutical products comprise formulations that have misspelled, absent, or incorrect label, as well as unknown or differently marketed chemical compositions/concentrations. Given that differences in the stated concentration of the active ingredients and the amounts detected in formulations also characterize signs of falsification, the extraction methods applied should retrieve the analytes quantitatively in the preparation 5,10 . Evaluation of the extractive protocols showed that generally the use of conventional methods (liquid–liquid, solid–liquid, or ultrasonic bath) had lower retrievals of the active ingredient compared with microwave assisted and ultrasonic probe.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Besides, AASs can exist as polymorphs, which can alter the aspect and position of bands in the spectra and hamper the detection of the AAS (Chiong et al, 1992). In this sense, IR spectroscopy is generally used as a complementary and screening technique to further analytical tools (Berneira et al, 2019). Recently, IR spectroscopy has been combined with chemometry tools including principal component analysis (PCA) and partial least squares-discriminant analysis (PLS-DA) in order to detect possible falsifications or adulterations in a questioned sample based on previous results of supposed similar samples (Neves et al, 2016;Rebiere et al, 2016).…”
Section: Ir Spectroscopymentioning
confidence: 99%