2012
DOI: 10.1016/j.talanta.2012.01.021
|View full text |Cite
|
Sign up to set email alerts
|

Application of DV-SIA manifold for determination of thiocyanate ions in human saliva samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2014
2014
2025
2025

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(14 citation statements)
references
References 24 publications
0
14
0
Order By: Relevance
“…Therefore, the developed method is more environmentally friendly and cheaper. Moreover, phase separation 28,42,43 and transfer of the extraction phase to a microvolume cell are excluded. As a consequence, the method can be considered as simpler and less time consuming.…”
Section: Analytical Applicationmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, the developed method is more environmentally friendly and cheaper. Moreover, phase separation 28,42,43 and transfer of the extraction phase to a microvolume cell are excluded. As a consequence, the method can be considered as simpler and less time consuming.…”
Section: Analytical Applicationmentioning
confidence: 99%
“…For the rst time, an optical probe is proposed as the holder of the extraction drop and the measuring cell in a direct immersion single-drop microextraction. In the proposed DI-SDME scheme the necessity of transferring the extraction phase to a microcuvette 28,42 or the pedestal of a cuvetteless spectrophotometer as well as dispensing to a ow cell 28,43 for absorbance measurement is eliminated. This makes the analysis simpler and less time-consuming and allows the absorbance to be recorded online.…”
Section: Conclusion and Future Researchmentioning
confidence: 99%
“…The concentration of thiocyanate in biological samples can be determined by different methodsgravimetric , titrimetric , electrochemical , kinetic, chromatographic, atomic , Roentgen , spectrophotometric (2,(10)(11)(12)To determine the concentration of thiocyanates in blood serum and urine we applied our modified spectrophotometric method Giraudi and Grillo (10), which allows the biomarker to be determined in two biodegradables -urine and blood serum. Lower limit of detection of the method allows to reduce the volume of samples analyzed and the volumes of reagents used.…”
Section: Thiocyanates -Quantitative Criterion For Smoking and Its Intmentioning
confidence: 99%
“…The method is fast and its technical execution is easy -requires the addition of only two reagents to the pre-treated samples, which makes it applicable for serial analyzes. Indicator for the relevance of the method is the data collected from the literature review -the method of Giraudi and Grillo is one of the most quoted and used spectrophotometric methods (11,12).…”
Section: Thiocyanates -Quantitative Criterion For Smoking and Its Intmentioning
confidence: 99%
“…One solution based on a dual-valve sequential injection manifold (DV-SIA) employing two separate SIA units connected with the extraction chamber by a tubing system was reported [21][22][23]. The SV-SIA manifold recently suggested by our lab [24] provides another conception in that it allows the entire procedure to be carried out in a single SIA unit.…”
Section: Introductionmentioning
confidence: 99%