1997
DOI: 10.1107/s0909049597093291
|View full text |Cite
|
Sign up to set email alerts
|

Application of Energy-Resolved Measurements to Laue Diffraction: Determination of Unit-Cell Parameters, Deconvolution of Harmonics and Assignment of Systematic Absences

Abstract: The use of energy-resolved area detection of Laue diffraction patterns for the determination of unitcell parameters and systematic absences is demonstrated. Seven different crystals having previously known unit cells were re-examined using Laue diffraction methods. These crystals included four different crystal systems including cubic, orthorhombic, tetragonal and monoclinic cells. The crystals had cell sizes ranging from 179.4 to 4588.3 A~. Comparison of known and re-determined cells showed good agreement (ra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2001
2001
2009
2009

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 20 publications
0
9
0
Order By: Relevance
“…We attempted to evaluate the variation in unit-cell parameters within and between drops. Determination of accurate absolute values of unit-cell parameters from Laue data requires special measures such as a filter which produces a sharp edge in the X-ray spectrum (Carr et al, 1993) or an energy-resolving detector (Hanley et al, 1997), owing to uncertainty in the exact X-ray wavelength producing each spot in 'simple' data (Ravelli et al, 1996). However, ratios between unit-cell parameters can routinely be refined.…”
Section: Evaluation Of Datamentioning
confidence: 99%
“…We attempted to evaluate the variation in unit-cell parameters within and between drops. Determination of accurate absolute values of unit-cell parameters from Laue data requires special measures such as a filter which produces a sharp edge in the X-ray spectrum (Carr et al, 1993) or an energy-resolving detector (Hanley et al, 1997), owing to uncertainty in the exact X-ray wavelength producing each spot in 'simple' data (Ravelli et al, 1996). However, ratios between unit-cell parameters can routinely be refined.…”
Section: Evaluation Of Datamentioning
confidence: 99%
“…The mathematical model would then be: where ss 1 and ss 2 , are the sum of squared residuals for the reduced and complete models, respectively; k is the number of parameters for the complete model; g is the number of parameters for the reduced model; n is the number of data points; k-g corresponds to the number of degrees of freedom for the numerator, ν 1 ; and n-k corresponds to the number of degrees of ‡ The treatment given here is similar to one presented by Scheaffer and McClave 32 The main difference between the two treatments is that the degrees of freedom for the denominator is given here as n-k as opposed to n-(k+1). The latter assumes that there is a constant term in the model that is not included in the value of k. See also Hanley et al 34 for a description of related use of the F-test for model building. H a = The inclusion of the additional parameters is justified.…”
Section: Theory Sectionmentioning
confidence: 99%
“…One approach to unscrambling harmonics, determining units cells and assigning space groups is a system of calibrated absorbers allowing the energy of individual spots to be determined. One approach to this was a foil mask spectrometer system which was capable of determining small unit cells and assigning systematic absences to spots containing harmonic overlap (Hanley et al, 1997). Separation of harmonic content of Laue diffraction spots has been treated in some detail both theoretically and experimentally (Hanley et al, 1996(Hanley et al, , 1997 and will not be treated at length here.…”
Section: Laue Diffraction Revisitedmentioning
confidence: 99%
“…One approach to this was a foil mask spectrometer system which was capable of determining small unit cells and assigning systematic absences to spots containing harmonic overlap (Hanley et al, 1997). Separation of harmonic content of Laue diffraction spots has been treated in some detail both theoretically and experimentally (Hanley et al, 1996(Hanley et al, , 1997 and will not be treated at length here. It is, however, likely that any improvements in foil mask spectrometers will improve the ability to separate harmonics.…”
Section: Laue Diffraction Revisitedmentioning
confidence: 99%
See 1 more Smart Citation