2012
DOI: 10.1016/j.jelechem.2012.08.014
|View full text |Cite
|
Sign up to set email alerts
|

Application of genetic algorithm for baseline optimization in standard addition voltammetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 37 publications
0
4
0
Order By: Relevance
“…The superhydrophobic properties of coatings are also in interest of scientists [43]. Research groups have been collaborating with international groups from Germany [44][45][46][47], Japan [48][49][50][51][52], France [53], Algeria [54] [87][88][89][90][91] is also an important issue for scientists. The topic of SOFC [92] is explored as well.…”
Section: Agh University Of Science and Technologymentioning
confidence: 99%
“…The superhydrophobic properties of coatings are also in interest of scientists [43]. Research groups have been collaborating with international groups from Germany [44][45][46][47], Japan [48][49][50][51][52], France [53], Algeria [54] [87][88][89][90][91] is also an important issue for scientists. The topic of SOFC [92] is explored as well.…”
Section: Agh University Of Science and Technologymentioning
confidence: 99%
“…In this context, the appropriate baseline subtraction method is of great relevance. Different algorithms for baseline subtraction have been proposed [97][98][99] and the software of modern electrochemical instruments includes integrated routines to perform this task. Figure 4B illustrates how appropriate definition of the baseline affects the current to be measuredthe same is applicable for peak areas -using ASV as an example.…”
Section: Sample Preparation and Optimizationmentioning
confidence: 99%
“…In order to solve the abovementioned issue instrumental, chemical and mathematical approaches are reported. Among them: elimination of capacitive current [9], lowering the background current [10,11], increasing the analytical signal as a result of employing catalytic processes [12][13][14], enhancement an analyte transport to the electrode surface by means of vibrating electrodes [15][16][17] or ultrasounds [18][19][20], analytes preconcentration at very negative potentials [21,22], application of interdigitated microelectrode arrays [23] or ring-disk electrode [24] and other ways [25] were reported.…”
Section: Introductionmentioning
confidence: 99%