Application of Partial Discharge Testing to Hydro Generator Maintenance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0

Year Published

1986
1986
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 95 publications
(26 citation statements)
references
References 6 publications
0
25
0
Order By: Relevance
“…However, as more exposed than neutral to noise from transformer and power system, extra noise suppression might be necessary for HV terminal detecting methods. Kurtz et al [49] modified the off-line test system described by Johnson [50] by replacing the large coupling capacitor with an appreciably smaller one of about 80 pF connected with a resistive detection impedance, which was the predecessor of the subsequent PD analyzer (PDA), i.e., HVCC. PDA includes differential and directional modes.…”
Section: Hv Terminal Detecting Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, as more exposed than neutral to noise from transformer and power system, extra noise suppression might be necessary for HV terminal detecting methods. Kurtz et al [49] modified the off-line test system described by Johnson [50] by replacing the large coupling capacitor with an appreciably smaller one of about 80 pF connected with a resistive detection impedance, which was the predecessor of the subsequent PD analyzer (PDA), i.e., HVCC. PDA includes differential and directional modes.…”
Section: Hv Terminal Detecting Methodsmentioning
confidence: 99%
“…If an internal circuit ring with sufficient length exists, the best installation is a differential mode, as shown in Figure 6a. One coupling capacitor per line end of each parallel is installed and helps to separate PD from noise stemmed from outside generator by time of arrival and pulse characteristics [49,51]. When there is insufficient circuit ring to install coupling capacitors at least 2 m apart, a directional installation is required, as shown in Figure 6b [51].…”
Section: Hv Terminal Detecting Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…There has also been increasing interest by the electrical manufacturers and power utilities in the use of on-line PD monitoring as a diagnostic for locating incipient faults in cables [104], transformers [105], and rotating machinery [106]. Table 4 [129].…”
Section: Heatingmentioning
confidence: 99%
“…For the Westinghouse method, PD currents are detected in the neutral grounding connection of the generator by means of an hf current transformer [7,8]. The partial discharge analyzer (PDA) developed by Ontario Hydro found worldwide application for hydro generators [9]. To discriminate between PDs and interference, for each phase two capacitive sensors are installed in the circuit-ring-bus.…”
Section: Introductionmentioning
confidence: 99%