1997
DOI: 10.1016/0960-1481(96)00062-6
|View full text |Cite
|
Sign up to set email alerts
|

Application of passive downdraught evaporative cooling (PDEC) to non-domestic buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2000
2000
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(7 citation statements)
references
References 2 publications
0
6
0
1
Order By: Relevance
“…Some studies indicated that bigger droplets may create airflow toward the bottom as they transfer momentum to the air stream [22,25]. Yet, the results of this study showed that outlet air velocities were fairly constant with almost no variation, ranging from 0.76 m/s to 0.79 m/s.…”
Section: Droplet Sizementioning
confidence: 59%
See 1 more Smart Citation
“…Some studies indicated that bigger droplets may create airflow toward the bottom as they transfer momentum to the air stream [22,25]. Yet, the results of this study showed that outlet air velocities were fairly constant with almost no variation, ranging from 0.76 m/s to 0.79 m/s.…”
Section: Droplet Sizementioning
confidence: 59%
“…Additionally, previous studies focused mostly on the quantification of energy savings even though PDEC towers affect extensively the indoor thermal environment and indoor air quality. In fact, a number of approaches have been used to explain both the down-draft evaporative cooling process and the resulting indoor environments that they create such as post occupancy surveys, field experiments, building simulation, and computational fluid dynamics (CFD) analysis [1,4,5,[8][9][10]12,17,18,[20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36][37][38]. While such efforts have improved their performance to some extent, PDEC towers are still not commonly used as a low-energy solution in the cooling of buildings.…”
Section: Introductionmentioning
confidence: 99%
“…A wide range of experimental and computer based work suggests these technologies have a huge potential (Bowman et al, 1997;Bowman et al, 1998;Ford, 2009;Lain & Hensen, 2006;Moura & Ford, 2003;Schiano-phan, 2010;Short, Cook, & Lomas, 2009). In most of these studies the importance of analysing both macro (Kottek et al 2006) and micro (Hughes et al, 2012) climate is stated.…”
Section: Climatic Applicability Of Pdecmentioning
confidence: 99%
“…Given that electricity is the predominant energy source for air-conditioning plant, which in primary energy terms is far more environmentally important than direct fossil fuel combustion, the application of passive cooling techniques may be a potent means for reducing environmental emissions. Evaporative cooling has great potential in this respect [5]. …”
Section: Introductionmentioning
confidence: 99%