2014
DOI: 10.1016/j.electacta.2013.10.214
|View full text |Cite
|
Sign up to set email alerts
|

Application of polyaniline for potentiometric recognition of salicylate and its analogues

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…Various methods have been proposed for the determination of salicylic acid and its derivatives in biological liquids and pharmaceutical preparations: chromatography [ 4 , 5 ], spectroscopic [ 6 9 ], electrochemical [ 10 15 ]. Many spectrophotometric and electrochemical methods of salicylate determination are based on its ability of forming complexes with metals: colored complex of salicylate with iron (III) is used in the classical method of salicylate determination (Trinder test) in biological samples [ 6 ]; complexing reaction with transition metal ions is employed in ion-selective electrodes construction [ 12 – 14 ].…”
Section: Introductionmentioning
confidence: 99%
“…Various methods have been proposed for the determination of salicylic acid and its derivatives in biological liquids and pharmaceutical preparations: chromatography [ 4 , 5 ], spectroscopic [ 6 9 ], electrochemical [ 10 15 ]. Many spectrophotometric and electrochemical methods of salicylate determination are based on its ability of forming complexes with metals: colored complex of salicylate with iron (III) is used in the classical method of salicylate determination (Trinder test) in biological samples [ 6 ]; complexing reaction with transition metal ions is employed in ion-selective electrodes construction [ 12 – 14 ].…”
Section: Introductionmentioning
confidence: 99%
“…To the best of our knowledge, it is the first time to introduce a chemically modified carbon paste based sensor for salicylate determination and it proves to have good response characteristics among all the studied sensors. Also, the comparison of the CP based sensor ( B ) with the previously reported salicylate sensors 912, 6365 showed superior characteristics in terms of response time, linear range and detection limit, with the exception of 11, 12 which have wider linear range (Table 4).…”
Section: Comparison Of the Proposed Sensors With Some Of The Reportmentioning
confidence: 84%
“…This is because the resistance of the modified electrode surface is affected by the release of iodide. When the specific interaction between the PMS and anionic analytes occurs, the iodide diffuses and causes a decrease in resistance values [ 28 ].…”
Section: Resultsmentioning
confidence: 99%