2022
DOI: 10.1002/mabi.202200114
|View full text |Cite
|
Sign up to set email alerts
|

Application of Porous Polyetheretherketone Scaffold/Vancomycin‐Loaded Thermosensitive Hydrogel Composites for Antibacterial Therapy in Bone Repair

Abstract: Polyetheretherketone (PEEK) has been widely used in bone repair, but it often fails due to bacterial infection. Herein, a high‐strength porous polyetheretherketone scaffold (ps‐PK) loaded with antibacterial drug‐loaded hydrogel strategy is proposed. The prepared ps‐PK possesses high porosity (30.8–64.7%) and the compression modulus is between 0.4 and 0.98 GPa. The interconnected pore‐type structure endows it with a drug loading capacity. Poly(D,L‐lactic acid‐co‐glycolic acid)‐b‐Poly(ethylene glycol)‐b‐Poly(D,L… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 53 publications
0
6
0
Order By: Relevance
“…The good biocompatibility and suitable degradation time of the Gel were also important for wound treatments besides its thermosensitive feature. 55,56 Cytotoxicity and Intracellular Antioxidative Activity of MOF-818. Prior to evaluating the intracellular antioxidant capability, the cytotoxicity of MOF-818 was tested according to the standard CCK-8 assay.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The good biocompatibility and suitable degradation time of the Gel were also important for wound treatments besides its thermosensitive feature. 55,56 Cytotoxicity and Intracellular Antioxidative Activity of MOF-818. Prior to evaluating the intracellular antioxidant capability, the cytotoxicity of MOF-818 was tested according to the standard CCK-8 assay.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…As the temperature increased, a sol-to-gel phase transition occurred, which is suitable for its use in wound treatments. The good biocompatibility and suitable degradation time of the Gel were also important for wound treatments besides its thermosensitive feature. , …”
Section: Resultsmentioning
confidence: 99%
“…Qi et al 157 used PLGA–PEG–PLGA thermos-responsive hydrogels loaded with vancomycin on the surface of porous PEEK. It showed high inhibition rate against methicillin-resistant S. aureus in vitro.…”
Section: Surface Modification Substance Coatingsmentioning
confidence: 99%
“…PLGA has superior biodegradability when compared to other synthetic polymers due to the hydrolysis of ester bonds and auto-catalytic degradation. The hydrophobic PLGA block is usually combined with the hydrophilic PEG block to prepare thermo-responsive hydrogels [ 68 , 69 ].…”
Section: Polymers For Smart Hydrogelsmentioning
confidence: 99%