Application of power theory for electricity metering in presence of distortion

Abstract: At enterprises, electricity metering devices are used everywhere, which incorporate various formulas for calculating power. The division of power into active, reactive and full is valid only in the case of sinusoidal currents and voltages. In the case of non-sinusoidal waveforms of current and voltage, which are most often found in industrial networks of enterprises, it is necessary to use additional concepts and correct formulas for calculating powers in order to avoid errors. The article compares the methods… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 16 publications
0
3
0
Order By: Relevance
“…In this regard, the scientific community has been faced with a number of tasks, namely, the development of methods and devices for harmonics compensation, and the development of methods for assessing the impact of each nonlinear consumer on the quality of electricity at the PCC [12,13]. The first issue has been considered in detail in [14][15][16][17][18][19][20], and various configurations of active, passive, and hybrid harmonics filters have been proposed.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this regard, the scientific community has been faced with a number of tasks, namely, the development of methods and devices for harmonics compensation, and the development of methods for assessing the impact of each nonlinear consumer on the quality of electricity at the PCC [12,13]. The first issue has been considered in detail in [14][15][16][17][18][19][20], and various configurations of active, passive, and hybrid harmonics filters have been proposed.…”
Section: Introductionmentioning
confidence: 99%
“…HF are measured for the resonant frequency h. The previously installed filter can be used or an additional filter should be connected as part of the measuring equipment. All required data can be obtained by a standard power quality analyzer; • Calculations of the PSS contribution are made according to (12). If the utility is the dominant source (contribution is more than 50%), then no additional measures to eliminate harmonics at the consumer's side should be provided since the measures from the utility side are paramount.…”
mentioning
confidence: 99%
“…-The metering engineers had little or no interest in the subject since it was believed that the level of harmonics in the power system was not high enough to cause problems with revenue meters. [193] -The modern power metering devices contain formulas for calculating power, which do not take into account the influence of higher harmonics.…”
Section: Electrical Energy Billing Strategies -Related Workmentioning
confidence: 99%