1997
DOI: 10.1016/s0039-9140(96)02115-7
|View full text |Cite
|
Sign up to set email alerts
|

Application of sequential injection analysis to anodic stripping voltammetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
21
0
3

Year Published

1998
1998
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 52 publications
(24 citation statements)
references
References 10 publications
0
21
0
3
Order By: Relevance
“…Lukkari et al [42] used solid-phase extraction on Al oxide in a sequential injection system to purify pyrocatechol, protocatechuic acid, pyrogallol, and gallic acid in black liquor. Application of the SIA technique to anodic stripping voltammetry (ASV) allowed the on-line plating of the mercury film and therefore substantially reduced the generation of mercury waste [44]. Primary explosive azides in environmental samples were determined amperometrically using an SIA system [45].…”
Section: Historical Backgroundmentioning
confidence: 99%
“…Lukkari et al [42] used solid-phase extraction on Al oxide in a sequential injection system to purify pyrocatechol, protocatechuic acid, pyrogallol, and gallic acid in black liquor. Application of the SIA technique to anodic stripping voltammetry (ASV) allowed the on-line plating of the mercury film and therefore substantially reduced the generation of mercury waste [44]. Primary explosive azides in environmental samples were determined amperometrically using an SIA system [45].…”
Section: Historical Backgroundmentioning
confidence: 99%
“…10 Various stripping voltammetric methods that were automated by SIA have been reported. 5,6,[8][9][10][11][12] Mercury-based electrodes have been traditionally used to obtain high sensitivity and reproducibility, as well as a wide cathodic potential limit in the ASV of trace metals. Because of the toxicity of mercury and environmental regulations, however, mercury-free electrodes were developed.…”
Section: Introductionmentioning
confidence: 99%
“…9 Medidas voltamétricas ou amperométricas realizadas em fluxo melhoram a repetitividade dos resultados, uma vez que as condições de transporte de massa do seio da solução para a superfície do eletrodo são bastante reprodutíveis nas condições de vazão e diâmetro de tubos tipicamente utilizados em análise por injeção em fluxo (FIA) ou injeção sequencial (SIA). [10][11][12] Determinações voltamétricas e amperométricas de As(III) em sistemas de fluxo já foram descritas, [13][14][15][16] mas ainda foram pouco estudadas em sistemas SIA. 14 Duangthong e colaboradores 13 propuseram a determinação de As(III) e As(IV) por voltametria de pulso diferencial usando um eletrodo de filme de ouro depositado sobre carbono vítreo.…”
Section: Introductionunclassified
“…[10][11][12] Determinações voltamétricas e amperométricas de As(III) em sistemas de fluxo já foram descritas, [13][14][15][16] mas ainda foram pouco estudadas em sistemas SIA.…”
unclassified