2009
DOI: 10.1016/j.avsg.2009.06.001
|View full text |Cite
|
Sign up to set email alerts
|

Application of Shape Memory Alloy Pressure-Controlled Vascular Clamp for Atraumatic Vessel Occlusion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0
5

Year Published

2010
2010
2021
2021

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 14 publications
0
3
0
5
Order By: Relevance
“…[27][28][29][30][31][32][33] Other alternatives to clamping are an intraluminal balloon, a vessel loop, or vascular occluder gels, each with their own advantages and disadvantages. [27][28][29][30][31][32][33][34] Intraluminal balloons exert a compressive force directly at the intima, the most vulnerable part of an already diseased artery. Nevertheless, animal studies show that intraluminal balloons resulted in less damage to the vessel wall compared with regular clamps.…”
Section: Commentsmentioning
confidence: 99%
“…[27][28][29][30][31][32][33] Other alternatives to clamping are an intraluminal balloon, a vessel loop, or vascular occluder gels, each with their own advantages and disadvantages. [27][28][29][30][31][32][33][34] Intraluminal balloons exert a compressive force directly at the intima, the most vulnerable part of an already diseased artery. Nevertheless, animal studies show that intraluminal balloons resulted in less damage to the vessel wall compared with regular clamps.…”
Section: Commentsmentioning
confidence: 99%
“…In 2009, Zhang et al proposed a new hemostatic clamp using super elastic Shape Memory Alloy (SMA) as a pressure control limiter (15). In 2010, Glauber et al designed a detachable aortic clamping instrument to facilitate easier and safer manipulation during the procedure (9).…”
Section: Introductionmentioning
confidence: 99%
“…Incluso los denominados clamps atraumáticos provocan un considerable daño endotelial, proporcional a la fuerza de oclusión 2,3 . Las bandas de silicona o el torniquete de Rumel constituyen métodos no seguros de control del flujo sanguíneo en arterias gravemente calcificadas y también pueden ser causa de lesión vascular.…”
unclassified
“…Las bandas de silicona o el torniquete de Rumel constituyen métodos no seguros de control del flujo sanguíneo en arterias gravemente calcificadas y también pueden ser causa de lesión vascular. Dispositivos de control de la presión ejercida por el clamp han presentado bajos niveles de lesión endotelial 3,4 Figura 2 Poloxámero 407 dentro de los extremos proximal y distal de la arteria sin evidencia de sangrado. un método de oclusión no lesivo, pero dificultan de forma importante la realización de la línea de sutura 6 .…”
unclassified