2010
DOI: 10.4155/bio.10.88
|View full text |Cite
|
Sign up to set email alerts
|

Application of the DBS Methodology to a Toxicokinetic Study in Rats and Transferability of Analysis Between Bioanalytical Laboratories

Abstract: The results indicate that comparable concentration results are obtained from DBS and whole blood samples within the same laboratory, indicating that changing between the two matrices is viable. The comparable results of DBS samples analyzed at two laboratories using different analytical methodologies demonstrate that the technique is robust and transferable.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
15
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 32 publications
(15 citation statements)
references
References 18 publications
0
15
0
Order By: Relevance
“…In addition, there are much reduced analyte stability concerns in the dried sample [6,7]. Supporting the reliability of the technique, there are reports of concentration data obtained from DBS correlating well with those data obtained from analysis of liquid samples [8]. As it stands, DBS has cemented itself as an option in the regulated laboratory, despite reliability-related question marks over aspects such as the impact of differing hematocrit [9] and uncertainty over best means of internal standard addition [10].…”
mentioning
confidence: 87%
“…In addition, there are much reduced analyte stability concerns in the dried sample [6,7]. Supporting the reliability of the technique, there are reports of concentration data obtained from DBS correlating well with those data obtained from analysis of liquid samples [8]. As it stands, DBS has cemented itself as an option in the regulated laboratory, despite reliability-related question marks over aspects such as the impact of differing hematocrit [9] and uncertainty over best means of internal standard addition [10].…”
mentioning
confidence: 87%
“…These huge ethical benefits are excellent examples of the reduction and refinement aspects of the 3R principles, which link scientific excellence with humane use of laboratory animals . Reduction in the volume of blood drawn per time point enables the utilization of serial rather than composite sampling for better correlation of exposure and effect . On the other hand, the principal merits that DBS offers for clinical studies lie in its applicability for pediatric and juvenile studies and room temperature sample storage/shipping—a logistic advantage .…”
Section: Introductionmentioning
confidence: 99%
“…These constraints are greatly relieved by 'microsampling', resulting in the generation of DBS and allowing serial sampling from a strongly reduced amount of laboratory animals, including small rodents such as mice. This allows the replacement of composite pharmaco-or toxicokinetic profiles (obtained from different animals) by serial profiles (obtained within individual animals), which leads to higher data quality ( Clark et al, 2010, Turpin et al, 2010, Crawford et al, 2011. Apart from a large improvement in animal welfare, DBS sampling is also beneficial for the (pharmaceutical) companies involved.…”
Section: Analysis Of Therapeutic Drugs -Toxicokineticsmentioning
confidence: 99%