2021
DOI: 10.5194/amt-14-3481-2021
|View full text |Cite
|
Sign up to set email alerts
|

Application of the ECT9 protocol for radiocarbon-based source apportionment of carbonaceous aerosols

Abstract: Abstract. Carbonaceous aerosol is mainly composed of organic carbon (OC) and elemental carbon (EC). Both OC and EC originate from a variety of emission sources. Radiocarbon (14C) analysis can be used to apportion bulk aerosol, OC, and EC into their sources. However, such analyses require the physical separation of OC and EC. Here, we apply of ECT9 protocol to physically isolate OC and EC for 14C analysis and evaluate its effectiveness. Several reference materials are selected, including two pure OC (fossil “ad… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 66 publications
(90 reference statements)
0
3
0
Order By: Relevance
“…Here, we discuss six different analytical techniques (ATs; Table 1) that have been used for isolating EC (BC) for radiocarbon analysis: AT 1 (Gustafsson et al, 2009;Andersson et al, 2015), AT 2 (Zhang et al, 2012), AT 3 (Dusek et al, 2014;Zenker et al, 2017), AT 4 (Bernardoni et al, 2013), AT 5 (Liu et al, 2017), AT 6 (Huang et al, 2021).…”
Section: Thermal-optical Analysis and Isolation Of Black Carbonmentioning
confidence: 99%
See 2 more Smart Citations
“…Here, we discuss six different analytical techniques (ATs; Table 1) that have been used for isolating EC (BC) for radiocarbon analysis: AT 1 (Gustafsson et al, 2009;Andersson et al, 2015), AT 2 (Zhang et al, 2012), AT 3 (Dusek et al, 2014;Zenker et al, 2017), AT 4 (Bernardoni et al, 2013), AT 5 (Liu et al, 2017), AT 6 (Huang et al, 2021).…”
Section: Thermal-optical Analysis and Isolation Of Black Carbonmentioning
confidence: 99%
“…Prior to that, suitable (EC) reference materials for 14 C analysis on aerosols need to be defined. This is because, presently, only ambient filter samples are used in 14C inter-comparisons where the "true" f m is not known (Liu et al, 2017;Zenker et al, 2017;Huang et al, 2021). Therefore, despite similar or different results, the accuracy of all methods still remains impossible to decide.…”
Section: Perspective On the State-of-the-art And Recommendationsmentioning
confidence: 99%
See 1 more Smart Citation