2022
DOI: 10.1016/j.cclet.2021.08.119
|View full text |Cite
|
Sign up to set email alerts
|

Applications of ambient electric arc ionization mass spectrometry in saline samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 33 publications
0
3
0
Order By: Relevance
“…It generates high voltage and high-frequency arcs and a series of reactive species that react with the analyte and produce ions. However, the stability of arc-plasma ionization can be influenced by air humidity, air flow and the atmospheric pollutants around the ion source . Additionally, the substantial amount of heat generated by the arc discharge makes it challenging to analyze thermally labile compounds, and the accumulation of heat also restricts long-time operation.…”
Section: Resultsmentioning
confidence: 99%
“…It generates high voltage and high-frequency arcs and a series of reactive species that react with the analyte and produce ions. However, the stability of arc-plasma ionization can be influenced by air humidity, air flow and the atmospheric pollutants around the ion source . Additionally, the substantial amount of heat generated by the arc discharge makes it challenging to analyze thermally labile compounds, and the accumulation of heat also restricts long-time operation.…”
Section: Resultsmentioning
confidence: 99%
“…30−33 Ambient electric arc ionization and direct analysis in real time (DART) realized analysis of quinolones and benzodiazepines in salts solutions directly. 34,35 However, when the analytes exist in more complex matrices, background interference became more laborious and difficult to overcome. 36 Therefore, there is a necessity to develop a method with a convenient device that can tolerate high salts and complex matrices to realize rapid detection of drugs.…”
mentioning
confidence: 99%
“…There are some methods that achieved satisfactory rapid detection of drugs. Dielectric barrier discharge ionization (DBDI) combined with nanometer metal probe, and desorption corona beam ionization (DCBI) were applied on the detection of antimicrobials in organisms and animal-derived foods, respectively. Ambient electric arc ionization and direct analysis in real time (DART) realized analysis of quinolones and benzodiazepines in salts solutions directly. , However, when the analytes exist in more complex matrices, background interference became more laborious and difficult to overcome . Therefore, there is a necessity to develop a method with a convenient device that can tolerate high salts and complex matrices to realize rapid detection of drugs. …”
mentioning
confidence: 99%