2018
DOI: 10.1016/j.jct.2017.12.019
|View full text |Cite
|
Sign up to set email alerts
|

Aqueous solutions of [EMIM] 1,1,2,2-tetrafluoroethanesulfonate and [EMIM] trifluoromethanesulfonate: A thermodynamic study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 28 publications
0
4
0
Order By: Relevance
“…As a basis for testing and extending the selected GCM models, an Excel database of IL melting point data was compiled (see Supplementary Materials ) from a variety of literature sources, including the NIST ILThermo database [ 61 ], a physicochemical properties reference book for ILs [ 62 ], and individual journal papers [ 14 , 45 , 51 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 , 79 , 80 , 81 , 82 , 83 , 84 , 85 , 86 , 87 , 88 , 89 , 90 , 91 , 92 , 93 , 94 , 95 , 96 , 97 , 98 , 99 , 100 , 101 , 102 , 103 , 104 , 105 , 106 , 107 , 108 ,…”
Section: Methodsmentioning
confidence: 99%
“…As a basis for testing and extending the selected GCM models, an Excel database of IL melting point data was compiled (see Supplementary Materials ) from a variety of literature sources, including the NIST ILThermo database [ 61 ], a physicochemical properties reference book for ILs [ 62 ], and individual journal papers [ 14 , 45 , 51 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 , 79 , 80 , 81 , 82 , 83 , 84 , 85 , 86 , 87 , 88 , 89 , 90 , 91 , 92 , 93 , 94 , 95 , 96 , 97 , 98 , 99 , 100 , 101 , 102 , 103 , 104 , 105 , 106 , 107 , 108 ,…”
Section: Methodsmentioning
confidence: 99%
“…Details of the experimental equipment and procedure have been described by us previously. 21 The standard uncertainty of the sample composition was estimated to be u(x w ) = 1 × 10 −4 and that of the freezing temperature measurements to be u(T) = 0.1 K. 2 together with parameters of the Redlich−Kister polynomial providing their adequate fit. Figure 1 shows the comparison of our results with the reference data originated from complete pTxy measurements using a recirculation VLE still, as carried out in National Physical Laboratory (Teddington, UK).…”
Section: Methodsmentioning
confidence: 99%
“…Details of the experimental apparatus and procedure have already been described. 3 The standard uncertainty of the freezing temperature and composition is estimated to be u(T) = 0.1 K and u(x w ) = 5 × 10 −4 , respectively.…”
Section: Phase Transitionmentioning
confidence: 99%
“…NRTL model has been widely proved to perform adequately for the purpose in our previous studies. [1][2][3][4][5][6]8 Bearing in mind that the selection of accurate data and rational fitting strategy are also important prerequisites for establishing a globally performing model, the procedure we adopted for the evaluation of adjustable parameters was as follows. For the (water + [BMPYR][OTF]) system, the VLE and H E data measured in this work were simultaneously correlated using the weighted least-squares method, the objective function minimalized being…”
Section: Phase Equilibria and Thermalmentioning
confidence: 99%