Arc Flash and Coordination Study Conflict in an Older Industrial Plant

Abstract: Once arc flash hazard analysis became a requirement for many industrial power system studies, the reduction of arc flash hazards has become an important concern. Inevitably, the factors that lead to reductions in arc flash hazards do not always lead to an improvement in other areas, in particular, protective device coordination. This paper will examine several particular cases where an arc flash hazard analysis of an older industrial plant yielded several cases of buses where the hazard level was "Extreme Dang… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 3 publications
0
1
0
Order By: Relevance
“…Therefore, finding the optimum settings of OCRs that consider the AFIE categories, definite regions, and DGs would provide a significantly more secure environment for workers and equipment. Several studies have used a light sensor (energy sensor) or differential protection to detect the occurrence of AF [36][37][38][39]. The occurrence of AF with circuit breakers inside sub-stations makes it possible to use the existing voltage transformers inside those substations to obtain voltage readings, which can be implemented in the inverse TCC of the overcurrent relay to obtain the least possible time in case of fault, as well as the possibility of adjusting the TCC within the numerical OCRs that are commonly installed and utilized in the existing DNs.…”
Section: Problem Description: Arc-flash Protectionmentioning
confidence: 99%
“…Therefore, finding the optimum settings of OCRs that consider the AFIE categories, definite regions, and DGs would provide a significantly more secure environment for workers and equipment. Several studies have used a light sensor (energy sensor) or differential protection to detect the occurrence of AF [36][37][38][39]. The occurrence of AF with circuit breakers inside sub-stations makes it possible to use the existing voltage transformers inside those substations to obtain voltage readings, which can be implemented in the inverse TCC of the overcurrent relay to obtain the least possible time in case of fault, as well as the possibility of adjusting the TCC within the numerical OCRs that are commonly installed and utilized in the existing DNs.…”
Section: Problem Description: Arc-flash Protectionmentioning
confidence: 99%