2019
DOI: 10.24425/ather.2019.129540
|View full text |Cite
|
Sign up to set email alerts
|

Archives of Thermodynamics

Abstract: Experimental research has been carried out for four individual heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend and U-bend with turbulator. Tests were made for the water-water system. The study covered a wide measuring range, i.e., Re = 800-9000 -on the shell side, for a constant cold water temperature of 9 • C and hot water of 50 • C. The heat exchangers were made from copper tubes with external diameter of 10 mm and 18 mm respectively and wall thickness of 1 mm. The… Show more