Argon Cold Plasma Use and Driveline Infection in Left Ventricular Assist Device Implant Recipients

Volker Lauenroth,
Armin Zittermann,
Stefan Lucke
et al.

Abstract: We conducted a prospective open-labeled, clinical trial, with a two-by-two factorial design, of argon cold plasma (ACP) application and two different types of driveline positioning for the prevention of driveline infection (DLI) in patients with a left ventricular assist device (LVAD) implant. Here, we present the results of ACP application versus no ACP application. Eighty patients were allocated to the control group (no preventive ACP use; n = 40) or ACP group (preventive ACP use for 30 days post-LVAD implan… Show more