2001
DOI: 10.1016/s0305-4179(00)00088-7
|View full text |Cite
|
Sign up to set email alerts
|

Arterial thermodilution: an alternative to pulmonary artery catheter for cardiac output assessment in burn patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
26
0
4

Year Published

2002
2002
2023
2023

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 59 publications
(31 citation statements)
references
References 23 publications
1
26
0
4
Order By: Relevance
“…A high degree of correlation between CO pa and CO tp has been established in multiple experimental and clinical settings including cardiac surgery patients, intensive care patients, septic patients, and burn victims (7,14,26,29,38,50,57,89,113). For instance, Sakka et al (89) studied 37 surgical ICU patients, 34 of whom had sepsis.…”
Section: Data Derived From Thermodilution Measurementsmentioning
confidence: 99%
“…A high degree of correlation between CO pa and CO tp has been established in multiple experimental and clinical settings including cardiac surgery patients, intensive care patients, septic patients, and burn victims (7,14,26,29,38,50,57,89,113). For instance, Sakka et al (89) studied 37 surgical ICU patients, 34 of whom had sepsis.…”
Section: Data Derived From Thermodilution Measurementsmentioning
confidence: 99%
“…17 Recently, we reported on the use of ICG for invasive monitoring and guidance of fluid therapy of severely burned patients during the resuscitation period. 18,19 After intravenous injection, ICG completely binds to plasma proteins and is exclusively distributed in the intravascular space. 20 This makes it a suitable tracer for vessel perfusion.…”
Section: Indocyanine Greenmentioning
confidence: 99%
“…Der Swan-Ganz-Katheter wird über eine großlumige zentralvenöse Schleuse eingeführt, die bei ohnehin erhöhter Gefahr einer Sepsis bei Brandverletzten einen zusätzlichen potenziellen Fokus darstellt. In kürzlich publizierten Arbeiten, wurden weniger invasive Methoden zum hämodynamischen Monitoring Brandverletzter eingesetzt [18,19,12,13]. Diese beruhen auf einer transkardiopulmonalen Einzel (Kälte)-oder Doppelindikatorverdünnung (Kälte plus Farbstoff).…”
Section: Transkardiopulmonale Indikatordilutionunclassified
“…Die Berechnung des Herzzeitvolumens erfolgt dann, wie bei der pulmonalarteriellen Thermodilution, nach der Steward-Hamilton-Gleichung [18]. Für diese Techniken konnte im Vergleich zum Swan-Ganz-Katheter eine gute Korrelation der gemessenen hämo-dynamischen Parameter gezeigt werden [18,12]. Nur bei sehr hohem Herzindex (>5,5) zeigte sich eine Diskrepanz zwischen transkardiopulmonaler und pulmonalarterieller Thermodilution [18].…”
Section: Transkardiopulmonale Indikatordilutionunclassified