“…The method of mechanical testing reported differs from some previous pastern arthrodesis studies, that used either axial loading of the limb, in an attempt to simulate in vivo loading, 16,18 or 3-point bending. 19,20 Difficulty in attaining pastern failure in axial loading has been reported, so it was not used for this study. 20,21 Rather, we elected to remove all of the soft tissue and perform 4-point bending mechanical testing of the paired constructs.…”