2018
DOI: 10.1016/j.recote.2018.03.002
|View full text |Cite
|
Sign up to set email alerts
|

Arthrodesis of the proximal interphalangeal joint of the 4th and 5th finger using an interlocking screw device to treat severe recurrence of Dupuytren's disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
22
0
12

Year Published

2021
2021
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(34 citation statements)
references
References 14 publications
0
22
0
12
Order By: Relevance
“…There were 2 studies 15 , 20 that documented mean pain via the Visual Analogue Scale (VAS), which ranged from 1.8 to 2.6, on a 10-point scale, postoperatively. Satisfaction was recorded in 2 studies 15 , 17 using VAS and in 4 studies 18 , 20 - 22 qualitatively. Using VAS, the mean and median satisfaction scores reported were 6.3 and 8, respectively.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…There were 2 studies 15 , 20 that documented mean pain via the Visual Analogue Scale (VAS), which ranged from 1.8 to 2.6, on a 10-point scale, postoperatively. Satisfaction was recorded in 2 studies 15 , 17 using VAS and in 4 studies 18 , 20 - 22 qualitatively. Using VAS, the mean and median satisfaction scores reported were 6.3 and 8, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…15,17 Qualitatively, the rate of satisfaction ranged from 56% to 100%. 18,[20][21][22] A mean QuickDASH score of 16.5 was reported in 1 study. 15 Other studies reported DASH scores where a score of 0 shows no disability and a score of 100 complete disability, as median 17 (33) or mean 18,20,22 (range from 15 to <35.04).…”
Section: Qualitative Outcomesmentioning
confidence: 93%
See 1 more Smart Citation
“…Nevertheless, in the studies included in this systematic review, there is a trend towards techniques with compression over the course of time, especially towards compression screws (41,42). With further development of the implants, the diameter of the screws got progressively smaller, as 8 mm diameter screws are commercially available now.…”
Section: Figurementioning
confidence: 99%
“…Newer implants like the Apex IP fusion device so far lack any evidence that they are easier to implant or provide a better outcome, maybe because they have not been available in the market long enough (42).…”
Section: Figurementioning
confidence: 99%