2007
DOI: 10.1016/j.neuroimage.2007.05.015
|View full text |Cite
|
Sign up to set email alerts
|

Artifact correction and source analysis of early electroencephalographic responses evoked by transcranial magnetic stimulation over primary motor cortex

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

9
109
1
5

Year Published

2012
2012
2020
2020

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 117 publications
(124 citation statements)
references
References 67 publications
9
109
1
5
Order By: Relevance
“…To correct for multiple comparisons (i.e., electrodes, time points within TOIs), a cluster-based permutation analysis (Maris and Oostenveld, 2007) was conducted as implemented in FieldTrip (http://fieldtrip.fcdonders.nl/; Litvak et al, 2007;Premoli et al, 2014a;Premoli et al, 2014b). A paired t test was applied to compare the postdrug versus baseline data within the same drug condition or postdrug data between different drug conditions for each electrode at each data point within the five different TOIs.…”
Section: Data Analysesmentioning
confidence: 99%
“…To correct for multiple comparisons (i.e., electrodes, time points within TOIs), a cluster-based permutation analysis (Maris and Oostenveld, 2007) was conducted as implemented in FieldTrip (http://fieldtrip.fcdonders.nl/; Litvak et al, 2007;Premoli et al, 2014a;Premoli et al, 2014b). A paired t test was applied to compare the postdrug versus baseline data within the same drug condition or postdrug data between different drug conditions for each electrode at each data point within the five different TOIs.…”
Section: Data Analysesmentioning
confidence: 99%
“…In recent years, the development of new technologies and solutions has gradually led to an improvement of the temporal resolution of EEG recording during TMS. Such strategies can be divided in two types: on-line strategies, which consists of the creation of technologies that are able to avoid saturating the EEG amplifiers during TMS (e.g., [42]) and off-line strategies, which aim to remove artefacts once the coregistration is completed (e.g., [44,68]). …”
Section: Technical Issuesmentioning
confidence: 99%
“…These procedures are more common in technical studies, often performed by biomedical and computer engineering equipment (e.g., [68,71]). Morbidi and colleagues, for example, proposed an off-line Kalman filter as a new effective and low-cost strategy for artefact reduction [71].…”
Section: Technical Issuesmentioning
confidence: 99%
See 1 more Smart Citation
“…However, this requires methods for removal of artifacts generated by the magnetic stimulation on the EEG signal. Very few offline mathematical solutions for TMS artifact removal have been proposed 16,21,22 , although no method is agreed upon, and no one method may be optimal for all experimental designs. A "clipping" system, consisting of a sample-and-hold circuitry, was also developed to momentarily stop EEG acquisition during TMS pulse delivery 20.…”
Section: Introductionmentioning
confidence: 99%