Artificial hearts are effective devices to treat heart failure in clinical practice and can be divided into two categories: artificial hearts and ventricular assist devices. The goal of this work was to investigate the fluidity and biological changes of in vitro sheep blood using a novel alternating current (AC) magnetohydrodynamic blood pump (central magnetic intensity: 0.9 T, alternating current frequency of the electric motor: 0–80 Hz). Blood samples were collected from five sheep and were divided into two groups: the control group (no exposure to an external magnetic field) and the exposed group (3 h of exposure to an alternating magnetic field). The blood cell counts, changes in blood viscosity, and ultrastructural changes of the blood cells under transmission electron microscopy were investigated. This study demonstrated several findings: (i) Continuous sheep blood flow can be achieved; (ii) The blood cell counts remained unchanged after 3 h of exposure to an alternating magnetic field; (iii) Compared with the control group, the high‐ and low‐shear viscosities of the whole blood from the sheep significantly decreased after 3 h of exposure to an alternating magnetic field (P < 0.05 and P < 0.01, respectively). Plasma viscosity was significantly reduced after exposure to high‐intensity alternating magnetic fields (P < 0.001); (iv) The cytoplasm of blood cells (especially erythrocytes) became lighter in color in the exposure group compared to the control group, and “beads‐on‐string” aggregations of black particles appeared. This work provides detailed and reliable scientific research data for the development of this type of blood pump, which may serve as a transition to the clinical artificial heart.
Artificial hearts are effective devices to treat heart failure in clinical practice and can be divided into two categories: artificial hearts and ventricular assist devices. The goal of this work was to investigate the fluidity and biological changes of in vitro sheep blood using a novel alternating current (AC) magnetohydrodynamic blood pump (central magnetic intensity: 0.9 T, alternating current frequency of the electric motor: 0–80 Hz). Blood samples were collected from five sheep and were divided into two groups: the control group (no exposure to an external magnetic field) and the exposed group (3 h of exposure to an alternating magnetic field). The blood cell counts, changes in blood viscosity, and ultrastructural changes of the blood cells under transmission electron microscopy were investigated. This study demonstrated several findings: (i) Continuous sheep blood flow can be achieved; (ii) The blood cell counts remained unchanged after 3 h of exposure to an alternating magnetic field; (iii) Compared with the control group, the high‐ and low‐shear viscosities of the whole blood from the sheep significantly decreased after 3 h of exposure to an alternating magnetic field (P < 0.05 and P < 0.01, respectively). Plasma viscosity was significantly reduced after exposure to high‐intensity alternating magnetic fields (P < 0.001); (iv) The cytoplasm of blood cells (especially erythrocytes) became lighter in color in the exposure group compared to the control group, and “beads‐on‐string” aggregations of black particles appeared. This work provides detailed and reliable scientific research data for the development of this type of blood pump, which may serve as a transition to the clinical artificial heart.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.