2010
DOI: 10.1016/j.compositesa.2010.06.008
|View full text |Cite
|
Sign up to set email alerts
|

Artificial lightning testing on graphite/epoxy composite laminate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

20
237
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 269 publications
(257 citation statements)
references
References 6 publications
20
237
0
Order By: Relevance
“…Maximum-scaled values for the plasma pressure, velocity and temperature versus time are also presented in Figure 8. The temperature results demonstrates that despite the air plasma core temperature being in the range of 10,000 K the cathode and anode surface temperature is only in the range of 300 K. This is due to the short time duration of the lightning strike event and is validated by experimental results [37,38,39] in which the cathode surface is not evaporated. Moreover, in certain lightning strike test setups a rubber head is installed near the cathode to reduce the lightning strike channel expansion pressure effects and again the rubber head is not typically damaged by heat.…”
Section: Resultssupporting
confidence: 54%
See 1 more Smart Citation
“…Maximum-scaled values for the plasma pressure, velocity and temperature versus time are also presented in Figure 8. The temperature results demonstrates that despite the air plasma core temperature being in the range of 10,000 K the cathode and anode surface temperature is only in the range of 300 K. This is due to the short time duration of the lightning strike event and is validated by experimental results [37,38,39] in which the cathode surface is not evaporated. Moreover, in certain lightning strike test setups a rubber head is installed near the cathode to reduce the lightning strike channel expansion pressure effects and again the rubber head is not typically damaged by heat.…”
Section: Resultssupporting
confidence: 54%
“…The lightning strike experimental configuration simulated is similar to the one used by Hirano et al [37], Ogasawara et al [38], and Feraboli & Miller [39] to inspect composite material performance. The calculation domain and boundary conditions are shown in Figure 2 and Table 3.…”
Section: Waveform-b Simulationmentioning
confidence: 99%
“…1 and 3). Both numerical and experimental studies of CFRP structures subjected to lightning strikes [12][13][14][15][16] proved that lightning still causes serious damage in such structures which extent dramatically increases when discharging occurs near metallic fasteners. In order to improve electrical conductivity of these materials various solutions of LSP of aircraft have been developed to-date.…”
Section: Overview On Lightning Strike Protection Solutions In Aircraftmentioning
confidence: 99%
“…4a and 5a. Once the sublimation temperature is reached, holes are created on the CFRP tanks because, above the decomposition temperature, the dielectric breaks down at the interlayer gaps [16] and surface recession occurs [14]. Throughout the analysis, the temperature of CFRP II is slightly less than that of CFRP I.…”
Section: Resultsmentioning