2015
DOI: 10.1371/journal.pone.0136551
|View full text |Cite
|
Sign up to set email alerts
|

Aspects of Dynamic Balance Responses: Inter- and Intra-Day Reliability

Abstract: The Posturomed device is used as a scientific tool to quantify human dynamic balance ability due to unexpected perturbations, and as a training device. Consequently, the question arises whether such measurements are compromised by learning effects. Therefore, this study aimed to analyze inter- and intra-day reliability of dynamic balance responses using the Posturomed. Thirty healthy young subjects participated (24.3±3.2 years). The Posturomed was equipped with a triggering mechanism to enable unexpected, hori… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
28
0
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(30 citation statements)
references
References 47 publications
1
28
0
1
Order By: Relevance
“…The Posturomed is widely applied as both training device and diagnostic tool . A good inter‐ and intra‐day reliability has been reported for the dynamic balance test on the Posturomed with intra‐class correlation coefficients ranging between 0.713 and 0.970 . This vertically suspended, unstable balance platform, which is mounted to eight springs and has been described in detail elsewhere, was equipped with a lever‐based provocation unit allowing unexpected horizontal perturbations to be applied in a standardized manner.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The Posturomed is widely applied as both training device and diagnostic tool . A good inter‐ and intra‐day reliability has been reported for the dynamic balance test on the Posturomed with intra‐class correlation coefficients ranging between 0.713 and 0.970 . This vertically suspended, unstable balance platform, which is mounted to eight springs and has been described in detail elsewhere, was equipped with a lever‐based provocation unit allowing unexpected horizontal perturbations to be applied in a standardized manner.…”
Section: Methodsmentioning
confidence: 99%
“…39 A good inter-and intra-day reliability has been reported for the dynamic balance test on the Posturomed with intra-class correlation coefficients ranging between 0.713 and 0.970. 40 This vertically suspended, unstable balance platform, which is mounted to eight springs and has been described in detail elsewhere, 41 was equipped with a lever-based provocation unit allowing unexpected horizontal perturbations to be applied in a standardized manner. The Posturomed was further fitted with the associated accelerometer to record oscillations, using the provided software (MicroSwing 5.0, Haider Bioswing GmBH, Germany).…”
Section: Proprioceptionmentioning
confidence: 99%
“…Failed attempts are noted as seconds until failure. Overall reliability of unexpected perturbed balance measurements was reported as good (interclass correlation (ICC) = 0.75-0.89) [25].…”
Section: Primary Endpointsmentioning
confidence: 98%
“…Participants are secured with a safety belt during all balance tests, which is a built-in safety feature included to prevent falls or other injuries. The balance setup exhibits a good inter-and intra-day reliability [78].…”
Section: Balance Testsmentioning
confidence: 98%
“…Dynamic balance tests The dynamic balance tests investigate the ability to withstand unexpected perturbations in the medio-lateral and anterior-posterior directions [33,78]. Participants are instructed to look straight ahead while keeping their knees straightened but not locked, and to keep their upper limbs hanging down at both sides, eyes opened.…”
Section: Balance Testsmentioning
confidence: 99%