2003
DOI: 10.1016/s0731-7085(03)00153-5
|View full text |Cite
|
Sign up to set email alerts
|

Assay and purity control of tetracycline, chlortetracycline and oxytetracycline in animal feeds and premixes by TLC densitometry with fluorescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
21
0
1

Year Published

2005
2005
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(22 citation statements)
references
References 13 publications
0
21
0
1
Order By: Relevance
“…Several analytical procedures are currently available for the determination of TC residues in animal tissues and at present chromatographic techniques are mainly used as confirmatory ones for these substances. Despite the simplicity and the low cost of TLC [14,15], HPLC coupled with UV [9, 16 -18], fluorescence [13,19], and MS [20 -23] remains the technique of choice for multiresidue analyses. Isolation of TCs from tissues includes an extraction step with a suitable solvent system and a clean-up procedure.…”
Section: Introductionmentioning
confidence: 99%
“…Several analytical procedures are currently available for the determination of TC residues in animal tissues and at present chromatographic techniques are mainly used as confirmatory ones for these substances. Despite the simplicity and the low cost of TLC [14,15], HPLC coupled with UV [9, 16 -18], fluorescence [13,19], and MS [20 -23] remains the technique of choice for multiresidue analyses. Isolation of TCs from tissues includes an extraction step with a suitable solvent system and a clean-up procedure.…”
Section: Introductionmentioning
confidence: 99%
“…Unmodified Silica gel 60 F 254 [92][93][94][95][96], Silica gel GF 254 [97], and Silica gel 60 H [98] are commonly used as the sorbent. Reversed-phase plates coated with silica gel with modifying -CN [97], C 8 , and C 18 [98] groups and cellulose-based sorbents [99,100] have been used in some works.…”
Section: Determination Of Organic Impurities In Pharmaceutical Preparmentioning
confidence: 99%
“…Reversed-phase plates coated with silica gel with modifying -CN [97], C 8 , and C 18 [98] groups and cellulose-based sorbents [99,100] have been used in some works. Silufol and Sorbfil plates are widely used in Russia [101,102].…”
Section: Determination Of Organic Impurities In Pharmaceutical Preparmentioning
confidence: 99%
“…For the determination of methacycline hydrochloride, high performance liquid chromatography [8] and antibiotics-microbial assay [9] were recommended in some pharmacopoeias. Only few studies on the method for determination of methacycline(MC) in pharmaceutical analysis are reported, including high performance liquid chromatography [10], spectrophotometry [11], phosphorimetry [12] and thin-layer chromatography [13][14]. Ion-selective electrodes are playing an important role in pharmaceutical analysis [15][16][17] due to its simplicity, rapidity and accuracy over some other analytical methods.…”
Section: Introductionmentioning