2012
DOI: 10.1016/j.enconman.2012.04.020
|View full text |Cite
|
Sign up to set email alerts
|

Assessing cooling energy performance of windows for residential buildings in the Mediterranean zone

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0
2

Year Published

2014
2014
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 54 publications
(25 citation statements)
references
References 29 publications
0
23
0
2
Order By: Relevance
“…It is calculated as the difference between the annual needs for covering the cooling requirements of the reference room with the examined window system (Q c ) and the annual needs for cooling requirements of a notional room (Q c,no win ), which is identical to the reference one, but its window is adiabatic (U = 0) and non-transparent to solar radiation (g = 0), divided by the surface of the window, A w [9,10,12]:…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…It is calculated as the difference between the annual needs for covering the cooling requirements of the reference room with the examined window system (Q c ) and the annual needs for cooling requirements of a notional room (Q c,no win ), which is identical to the reference one, but its window is adiabatic (U = 0) and non-transparent to solar radiation (g = 0), divided by the surface of the window, A w [9,10,12]:…”
Section: Methodsmentioning
confidence: 99%
“…More specifically, the authors have used the energy performance index of windows in order to identify their cooling energy performance in Mediterranean regions [9,10]. The work includes both residential [9] and office buildings [10], due to the fact that the internal heat gains and the ventilation modes vary significantly between these buildings types, leading to different window performance patterns as well as design concepts [11].…”
Section: Introductionmentioning
confidence: 99%
“…Each glazing is described by the thermal transmittance (U g -value) and solar transmittance (g-value), which are assumed to be calculated according to standards EN 673 and EN 410 respectively [1,2]. This is a simplified method of description, but the glazing energy transfer calculated based on these data has been proven to have acceptable accuracy for monthly calculations and has been widely used before [40,41]. The values of these parameters for each glazing analyzed are given in Table 2.…”
Section: Parameters Of Glazingsmentioning
confidence: 99%
“…How to be a more effective use of energy and how to save energy to find answers to the questions scientists have done studies [1]. It is necessary to know essential features such as carbon emission [2,3], building typology [4,5], cooling [6,7], ventilation [8,9] lighting [10] and heating system [11] in determining the energy performance of buildings. Also the studies in this area; the method of calculating the energy performance of buildings, the levels of intricate and detailed dynamic calculation method of calculating the simple activities of hours studied.…”
Section: Introductionmentioning