2020
DOI: 10.1002/fam.2875
|View full text |Cite
|
Sign up to set email alerts
|

Assessing smoke toxicity of burning combustibles by four expressions for fractional effective dose

Abstract: Summary Toxicity of smoke generated in a fire is difficult to measure accurately. That is because gas sensors for measuring rapidly varying concentrations of toxic gases are not yet developed. Simple expressions are searched for quick measurement in assessing smoke toxicity practically. Four equations on calculating fractional effective dose (FED) related to toxic effluents were reported in the literature, each based on different assumptions. FED value was proposed to be calculated based on peak carbon monoxid… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 26 publications
0
5
0
Order By: Relevance
“…FED was calculated following to Eq. (1) (ISO 13344: 1996); Chow et al 2020 of the animals that inhaled this mixture (Stec, 2017;Chow et al2020). The fire toxicity of materials can also be presented by lethal concentration (LC50).…”
Section: Introductionmentioning
confidence: 99%
“…FED was calculated following to Eq. (1) (ISO 13344: 1996); Chow et al 2020 of the animals that inhaled this mixture (Stec, 2017;Chow et al2020). The fire toxicity of materials can also be presented by lethal concentration (LC50).…”
Section: Introductionmentioning
confidence: 99%
“…FED equations given in ISO 13344 [19] are often simplified to consider only three gases, O 2 , CO, and CO 2 , measured using a CC for quick toxicity assessment [31]. The rationale behind this is that smoke toxicity can be reasonably assessed by considering only these three major gas species.…”
Section: Quantification Of Toxic Hazardsmentioning
confidence: 99%
“…where M is the mass loss during the combustion process and V is the total air volume in the apparatus at standard pressure and temperature (V can be assumed as 0.01 m 3 for bench scale testing) [31] (results summarized in Table A1).…”
Section: Quantification Of Toxic Hazardsmentioning
confidence: 99%
See 1 more Smart Citation
“…These fire hazard assessment models have been widely applied in building fire protection assessments. 22,23 In applications involving fire route analysis, search and rescue route analysis for firefighters considering smoke hazard has also been performed. 24 Crowd congestion is common in building fire.…”
Section: Introductionmentioning
confidence: 99%