2023
DOI: 10.1186/s13036-023-00332-0
|View full text |Cite
|
Sign up to set email alerts
|

Assessing the capabilities of 2D fluorescence monitoring in microtiter plates with data-driven modeling for secondary substrate limitation experiments of Hansenula polymorpha

Abstract: Background Non-invasive online fluorescence monitoring in high-throughput microbioreactors is a well-established method to accelerate early-stage bioprocess development. Recently, single-wavelength fluorescence monitoring in microtiter plates was extended to measurements of highly resolved 2D fluorescence spectra, by introducing charge-coupled device (CCD) detectors. Although introductory experiments demonstrated a high potential of the new monitoring technology, an assessment of the capabiliti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(6 citation statements)
references
References 71 publications
0
6
0
Order By: Relevance
“…The sampling broth was analyzed for pH value (HI21; HANNA instruments Inc., electrode: InLab Solids; Mettler Toledo GmbH), OD 600 , and carbon source concentrations. Except for a temperature of 60°C used during HPLC measurement, the procedure for the offline measurements was identical to the previous studies (Berg et al, 2022(Berg et al, , 2023. The linear correlation between OD 600 and CDW is given in Supporting Information: Figure 3.…”
Section: Offline Sampling and Analyticsmentioning
confidence: 99%
See 4 more Smart Citations
“…The sampling broth was analyzed for pH value (HI21; HANNA instruments Inc., electrode: InLab Solids; Mettler Toledo GmbH), OD 600 , and carbon source concentrations. Except for a temperature of 60°C used during HPLC measurement, the procedure for the offline measurements was identical to the previous studies (Berg et al, 2022(Berg et al, , 2023. The linear correlation between OD 600 and CDW is given in Supporting Information: Figure 3.…”
Section: Offline Sampling and Analyticsmentioning
confidence: 99%
“…The subsequent data processing, and MVDA were performed using MATLAB 9.10.0.1710957 (R2021a) Update 4 and the opensource toolbox mdatools (Kucheryavskiy, 2019). The post-experimental spectral processing steps were comparable to those described in Berg et al (2022Berg et al ( , 2023. The detected spectral range was reduced to include only intensities of λ em between −20 and +270 nm relative to the λ ex .…”
Section: Spectral Data Merging and Processingmentioning
confidence: 99%
See 3 more Smart Citations