1988
DOI: 10.1007/bf02583029
|View full text |Cite
|
Sign up to set email alerts
|

Assessment and maintenance of the quality of urolith analyses in a comparison of methods. 4th international ring test to check quality

Abstract: For five test samples of the fourth International Ring Test to check the quality of methods for urinary calculus analysis, 45 findings obtained by 10 different methods were sent from 16 countries. The mean deviation of 0.11 molecular parts per component for all five samples is considerably low. The average standard SQ for all participants is 2.44. It falls off from X-ray diffraction via IR down to other quantitative methods. Advantages and disadvantages of X-ray diffraction and IR-spectroscopic analyses are di… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0
2

Year Published

1989
1989
2014
2014

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 7 publications
0
3
0
2
Order By: Relevance
“…X-ray diffraction is also used, but it is unsuitable for the analysis of amorphous substances such as carbonate apatite. 2 Infrared spectroscopy is a reliable technique but it may produce complex spectra resulting from the interference of known biomaterial with unknown substances. 3 Thermal decomposition analysis is only suited for a few types of kidney calculi such as struvite.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…X-ray diffraction is also used, but it is unsuitable for the analysis of amorphous substances such as carbonate apatite. 2 Infrared spectroscopy is a reliable technique but it may produce complex spectra resulting from the interference of known biomaterial with unknown substances. 3 Thermal decomposition analysis is only suited for a few types of kidney calculi such as struvite.…”
mentioning
confidence: 99%
“…However, it is also the most inaccurate. X‐ray diffraction is also used, but it is unsuitable for the analysis of amorphous substances such as carbonate apatite 2. Infrared spectroscopy is a reliable technique but it may produce complex spectra resulting from the interference of known biomaterial with unknown substances 3.…”
mentioning
confidence: 99%
“…5,6 The simplicity of the sample treatment, the low cost associated with the measurements, and the usefulness of the obtained results have led infrared (IR) spectroscopy to become the reference method as well as the most widely used technique for urinary stones characterization. 7 In addition, some quantification methodologies based on IR spectroscopy have also been developed. In this regard, the most relevant bibliography describes linear quantification models based on the calculation of the ratio of single spectral bands (specific for each type of urinary stone), so most of the information on the spectra is not used into the calculations.…”
Section: Taking Advantage Of Hyperspectral Imaging Classification Of mentioning
confidence: 99%
“…Die Festlegung von SQ ergibt sich für die 5 Ringversuchsproben in Abhängigkeit von -der Komponentenanzahl pro Probe -der Zahl fehlender bzw. zusätzlich benannter Substanzen -der mittleren Abweichung (Mol-Anteile) von der Sollzusammensetzung der Probe nach einem Punktsystem (4 …”
Section: Bewertung Der Analysenergebnisseunclassified
“…Durch regelmäßige Qualitätskontroll-Ringversuche mit unterschiedlich zusammengesetzten Testproben werden die analytischen Möglichkeiten und Grenzen einzelner Analysetechniken aufgedeckt und Aussagen zur Richtigkeit der .erhobenen Befunde gewonnen (1)(2)(3)(4)(5)(6)(7)(8)(9)(10). Die Auffindung und Diskussion von Analysefehlern soll dabei helfen, zukünftig aufmerksamer und kritischer an die Beurteilung problematischer Harnsteinzusammensetzungen heranzugehen.…”
Section: Introductionunclassified