2017
DOI: 10.21608/edj.2017.76442
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Accuracy of Different Cad/Cam Fabricated Porcelain Laminate Veneers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

5
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 26 publications
5
4
0
Order By: Relevance
“…Regardless cementation, it was found that the highest statistically significant marginal gap values were recorded with E.max CAD, followed by Celtra Duo, while the lowest statistically significant marginal gap distance values were for VITA Suprinity. This was in agreement with some studies which proved that the E.max CAD specimens recorded higher vertical marginal gap mean values than that obtained with VITA Suprinity specimens (21) . This may be attributed to difficulties during restoration designing regarding scanning, digitization, and the milling process, milling burs size and the condition of the material during the milling procedure (22)(23)(24) .…”
Section: Discussionsupporting
confidence: 93%
“…Regardless cementation, it was found that the highest statistically significant marginal gap values were recorded with E.max CAD, followed by Celtra Duo, while the lowest statistically significant marginal gap distance values were for VITA Suprinity. This was in agreement with some studies which proved that the E.max CAD specimens recorded higher vertical marginal gap mean values than that obtained with VITA Suprinity specimens (21) . This may be attributed to difficulties during restoration designing regarding scanning, digitization, and the milling process, milling burs size and the condition of the material during the milling procedure (22)(23)(24) .…”
Section: Discussionsupporting
confidence: 93%
“…33 The first null hypothesis was rejected as there was significant difference regarding the marginal adaptation of occlusal veneers made of different materials. Celtra Duo showed lower marginal gap compared to IPS e.max CAD occlusal veneers, this result came in accordance with Ahmed, et al, (2020) (34) and Basheer, et al, (2017) 35 . Celtra Duo microstructure as claimed by the manufacturer to present high edge stability providing acceptable margins.…”
Section: Discussionsupporting
confidence: 85%
“…Regardless of cementation, it was found that the highest statistically significant marginal gap values were recorded with E-max followed by Celtra duo, followed by VITA Suprinity, while the lowest statistically significant marginal gap distance values were for VITA Enamic. This was in agreement with some studies which proved that the E.max CAD specimens recorded higher vertical marginal gap mean values than that obtained with VITA Enamic specimens (17) . This may be attributed to geometrical design of the restoration and difficulties regarding scanning, digitization, and the milling process of brittle ceramic material.…”
Section: Discussionsupporting
confidence: 93%