2010
DOI: 10.1093/eurheartj/ehq340
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of atherosclerosis: the role of flow-mediated dilatation

Abstract: Evidence suggests that endothelial dysfunction is on the causal pathway for both atherogenesis and destabilization of established plaques. In this review, the role of flow-mediated dilatation (FMD) as a non-invasive method to assess endothelial function is discussed. Technical modifications and development of analysis software have significantly improved the variability of the method. Following a strict standardized protocol enables reproducible measurements to be achieved and export of the technique from spec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
233
0
8

Year Published

2011
2011
2020
2020

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 255 publications
(244 citation statements)
references
References 100 publications
3
233
0
8
Order By: Relevance
“…19 This technique is particularly attractive as it is easy to repeat in patients, however there is still some variation between centres regarding image acquisition, for example in the time when measurements are obtained after cuff release so there still needs to be some standardization of the technique, though there have been attempts to do that. 20,21 Recently, FMD has shown good, reproducible results in multi-centre studies when rigorous methodology is used, perhaps suggesting that it will soon be able to be utilised in large prospective population studies as an outcome measure. 22,23 In a seven-centre study by Ghiadoni et al, the authors evaluated 135 adult healthy volunteers to assess reproducibility of FMD using a standardized protocol at 3 timepoints (baseline, 1 hour after baseline and 30 days after).…”
Section: Non-invasive Assessment Of Endothelial Functionmentioning
confidence: 99%
“…19 This technique is particularly attractive as it is easy to repeat in patients, however there is still some variation between centres regarding image acquisition, for example in the time when measurements are obtained after cuff release so there still needs to be some standardization of the technique, though there have been attempts to do that. 20,21 Recently, FMD has shown good, reproducible results in multi-centre studies when rigorous methodology is used, perhaps suggesting that it will soon be able to be utilised in large prospective population studies as an outcome measure. 22,23 In a seven-centre study by Ghiadoni et al, the authors evaluated 135 adult healthy volunteers to assess reproducibility of FMD using a standardized protocol at 3 timepoints (baseline, 1 hour after baseline and 30 days after).…”
Section: Non-invasive Assessment Of Endothelial Functionmentioning
confidence: 99%
“…Endothelial dysfunction can predict adverse CVD events and long-term outcomes (Schachinger et al 2000). Flow-mediated dilatation (FMD) represents the most widely used non-invasive ultrasound method to assess endothelial function, it measures endothelium-dependent vasorelaxation of the brachial artery (Charakida et al 2010).…”
Section: Endothelial Functionmentioning
confidence: 99%
“…Circulating abnormal levels of inflammatory markers and adhesive molecules have been associated with future cardiovascular risk [19,20]. However, high risk of mortality and cardiovascular morbidity is associated with OSA [21][22][23].…”
Section: Discussionmentioning
confidence: 99%