2015
DOI: 10.2172/1236174
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Automated Measurement and Verification (M&V) Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 8 publications
0
10
0
Order By: Relevance
“…(McLeod et al 2012) proposed a new method for the generation of current and future probabilistic micro regional climatic data in Passivhaus design, such data should provide a more robust basis for future cost and performance optimisation in low energy and passive building design. (Granderson et al 2015) reported documents the application of a general statistical methodology to assess the accuracy of baseline energy models, focusing on its application to Measurement and Verification (M&V) of whole-building energy savings. Low-cost energy saving and indoor comfort are the key directions for energy saving improvement in the future.…”
Section: Discussionmentioning
confidence: 99%
“…(McLeod et al 2012) proposed a new method for the generation of current and future probabilistic micro regional climatic data in Passivhaus design, such data should provide a more robust basis for future cost and performance optimisation in low energy and passive building design. (Granderson et al 2015) reported documents the application of a general statistical methodology to assess the accuracy of baseline energy models, focusing on its application to Measurement and Verification (M&V) of whole-building energy savings. Low-cost energy saving and indoor comfort are the key directions for energy saving improvement in the future.…”
Section: Discussionmentioning
confidence: 99%
“…CV(RMSE) (Coefficient of Variation of the Root Mean Square Error) measures the variability of the errors between measured and simulated values. It "gives an indication of the model's ability to predict the overall load shape that is reflected in the data" [19]. In this case, the value of p is suggested to be one [17,18].…”
Section: Measuring Uncertaintymentioning
confidence: 99%
“…Such examples have been taken from the most important journals and documents in the energy field, in particular the documents that use building calibrated models in their research. Obviously, in this search, there is a wide variety of articles, reports and theses where N MBE is used correctly [17][18][19]. Table 3 is an overview of these documents ordered by error type, journal/report/thesis and year published.…”
Section: References and Journals Affectedmentioning
confidence: 99%
“…This predicted energy consumption is then compared to the actual energy consumption of the building that had undergone a retrofit, to calculate real energy savings. Automated M&V tools provide a more cost-effective and timely way to calculate energy savings after a building retrofit (Granderson et al 2015).…”
Section: Estimation Of Potential Energy Savingsmentioning
confidence: 99%
“…Efforts were conducted by Lawrence Berkeley National Laboratory (LBNL) to develop a testing procedure and metrics to assess the performance of automated measurement and verification (M&V) tools (Granderson et al 2015). However, automated M&V tools serve a different purpose and audience than no touch audit technologies; they predict energy savings after a retrofit, rather than identify probable causes of high energy use.…”
Section: Introductionmentioning
confidence: 99%