2021
DOI: 10.1016/j.jjcc.2021.01.004
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of biventricular hemodynamics and energy dynamics using lumen-tracking 4D flow MRI without contrast medium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 14 publications
(22 citation statements)
references
References 26 publications
1
21
0
Order By: Relevance
“…Other studies of rTOF patients reported derangements of LV and RV KE [ 14 , 15 ], abnormal LV diastolic direct flow and increased recirculating residual volume in mild to moderate RV dilation [ 16 ]. In a recent study of 58 rTOF [ 17 ], the RV was systematically segmented into RV outflow (RVOT) and inflow components, and the respective 4D flow data were analyzed that could quantify intracardiac vorticity and energy loss [ 18 ]. Diastolic to systolic quotients of RVOT vorticities and viscous energy losses, both attributable to PR, were found to be significant negatively correlated with peak VO 2 and % predicted peak VO 2 [ 17 ].…”
Section: Introductionmentioning
confidence: 99%
“…Other studies of rTOF patients reported derangements of LV and RV KE [ 14 , 15 ], abnormal LV diastolic direct flow and increased recirculating residual volume in mild to moderate RV dilation [ 16 ]. In a recent study of 58 rTOF [ 17 ], the RV was systematically segmented into RV outflow (RVOT) and inflow components, and the respective 4D flow data were analyzed that could quantify intracardiac vorticity and energy loss [ 18 ]. Diastolic to systolic quotients of RVOT vorticities and viscous energy losses, both attributable to PR, were found to be significant negatively correlated with peak VO 2 and % predicted peak VO 2 [ 17 ].…”
Section: Introductionmentioning
confidence: 99%
“…A recent study showed that there was misalignment with only a few pixels between methods with and without breath holding in the cardiac PC images when no respiratory motion compensation was performed. 44 Sixth, the present method was not suitable for patients with transaortic flow higher than the VENC range because aliasing artifacts decrease the accuracy of flow quantification. However, when the VENC was set at a high velocity, the resolution of a moderate-flow field decreased, making discordant parameters and ambiguous or borderline judgments more probable.…”
Section: Limitationsmentioning
confidence: 85%
“…Each 4D flow dataset was imported into IT Flow (Cardioflow, Tokyo, Japan) [ 24 ] as separate segmentation masks to isolate velocity flow fields within the domains of interest. After background-phase correction, the masks were further screened to remove regions of noise artifact.…”
Section: Methodsmentioning
confidence: 99%
“…Viscous energy loss (VEL, mW) represent viscous dissipation across the flow field within each voxel, a combined effect of blood viscosity and velocity gradient (shear) [ 24 ]. For each direction, E is summated over repeated indices as: where is blood viscosity at 0.004 Pa·s.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation