2020
DOI: 10.1111/jvim.15805
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Brix refractometry to estimate immunoglobulin G concentration in beef cow colostrum

Abstract: Background Brix refractometry can be used to assess colostral immunoglobulin G (IgG) concentration, but studies identifying Brix percentages to detect high‐ and low‐IgG colostrum are lacking for beef cows and interlaboratory agreement is unknown. Objectives Evaluate Brix refractometer performance and interlaboratory agreement for assessing beef cow colostrum IgG concentration, including determination of thresholds to identify colostrum containing IgG concentrations <100… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
18
2
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(28 citation statements)
references
References 26 publications
6
18
2
2
Order By: Relevance
“…In general, beef cows should have a higher Ig concentration in the colostrum than dairy cows. This opinion is concordant with the studies of Gamsjäger et al (2020) [ 54 ], in which the cut-off points for low-IgG colostrum and high IgG colostrum for 416 colostrum samples from one beef breed deviate strongly from the normally used cut-off point of 50 mg IgG mL −1 . The cut-off point for low-IgG colostrum was at <100 mg mL −1, and the cut-off point for high-IgG colostrum was at ≥150 mg mL −1 .…”
Section: Factors Associated With Ig Concentration In Colostrumsupporting
confidence: 92%
See 2 more Smart Citations
“…In general, beef cows should have a higher Ig concentration in the colostrum than dairy cows. This opinion is concordant with the studies of Gamsjäger et al (2020) [ 54 ], in which the cut-off points for low-IgG colostrum and high IgG colostrum for 416 colostrum samples from one beef breed deviate strongly from the normally used cut-off point of 50 mg IgG mL −1 . The cut-off point for low-IgG colostrum was at <100 mg mL −1, and the cut-off point for high-IgG colostrum was at ≥150 mg mL −1 .…”
Section: Factors Associated With Ig Concentration In Colostrumsupporting
confidence: 92%
“…However, even in this study, the IgG concentration in the colostrum varied greatly (19.2–264.7 mg mL −1 ). These variations are also found in studies with dairy breeds [ 54 ]. The average IgG concentration measured using RID in a study by Elsohaby et al (2018) [ 43 ], including beef cows, was 143.2 mg mL −1 , just below the previously indicated cut-off point of 150 mg mL −1 .…”
Section: Factors Associated With Ig Concentration In Colostrumsupporting
confidence: 63%
See 1 more Smart Citation
“…36,37 may elect to use the Brix refractometer for serum IgG evaluation as well. On the other hand, many veterinarians have DSTP and OSTP available in their veterinary practice because of their multipurpose utility (eg, urine specific gravity, STP in adults and neonates), and their use should be encouraged for assessment of TPI in beef calves.In conclusion, DSTP, OSTP, and DBRIX all showed good utility for assessment of TPI status in neonatal beef calves, particularly for identification of calves with IgG concentrations below the target concentrations recommended recently for beef calves (IgG <16 or < 24 g/L).…”
mentioning
confidence: 99%
“…Colostrum samples were collected from 6 beef heifers (first parity) and 2 beef cows (third or higher parity) from 4 different privately owned cow-calf operations with either purebred Angus, Hereford, or Angus × Hereford crossbreds in southern Alberta, Canada. These samples were from 416 colostrum samples with extremely different IgG concentrations (Gamsjäger et al, 2020). Twenty milliliters of colostrum was collected manually, pooled from all teats into a clean plastic sampling cup, and stored at −80°C (Pearson et al, 2019a,b;Gamsjäger et al, 2020).…”
Section: Jdsmentioning
confidence: 99%